范文一:戴尔R720服务器安装步骤
戴尔R720服务器安装部署文档
目 录
1 准备工作 ............................................................................................................................................. 1 2 安装部署 ............................................................................................................................................. 1 2.1 步骤说明 ..................................................................................................................................... 1 3 开始部署 ............................................................................................................................................. 1 3.1 RAID 配置 ................................................................................................................................... 1 3.2 OS 部署 . ....................................................................................................................................... 3 3.3 安装系统 ..................................................................................................................................... 5
1 准备工作
准备一张光盘:Microsoft Windows Server 2008 32位SP2系统光盘
2 安装部署
2.1 步骤说明
1) 对RAID 进行配置 2) 对OS 进行引导部署 3) 对系统进行安装
3 开始部署
3.1 RAID 配置
1) 开机后,当屏幕出现press ctrl R 的提示,立即点击按键ctrl+R进入RAID 配置界面。如下图所示。
3-1 RAID配置界面
2) 通过上下键进行光标移动,在虚拟硬盘(Virtual Disks )下方硬盘上点击“F2”,对虚拟硬盘进行删除操作,选择“Delete VD”,点击enter 键确认删除原有虚拟硬盘。
3) 原有虚拟硬盘删除后,界面自动返回到初始未设置硬盘情况下,重新添加虚拟硬盘,将光标移动到顶部“PERC H310 Mini(Bus 0x03,Dev 0x00)”上点击“F2”,创建新的虚拟硬盘,选择“Create New VD”,点击enter 键确认。
4) 通过Tab 键或上下键切换光标到RAID Level后,点击enter 键,通过上下键选择RAID 5,点击enter 键确认;然后继续切换光标到(Physical Disks),下属物理硬盘,如图所示,依次勾选3个同样大小的硬盘,点击enter 键进行勾选;最后将光标切换到OK ,点击enter 键完成。
3-2 RAID 5配置情况
5) 再次通过顶部“PERC H310 Mini(Bus 0x03,Dev 0x00)”点击F2进入硬盘配置界面,为单独硬盘配置RAID 0,勾选单独的硬盘,点击enter 键进行勾选;最后将光标切换到OK ,点击enter 键完成。
3-3 RAID 0配置情况
6) 通过点击“Ctrl+N”可以切换菜单项,连续点击二次“Ctrl+N”切换页面到第三项“Ctrl Mgmt”,通过切换Tab 键,选择启动设备(Select boot device)为“VD 1 465.25 GB”此硬盘,点击enter 键确认,最后点击ESC 键返回,系统重启。
说明:若服务器只有3块同样大小的硬盘,只需把RAID 设置成RAID 5即可,无需(5)(6)步骤。
3.2 OS 部署
1)重启系统后,当界面右上角出现提示F10选项,立即点击“F10”进入到OS 部署界面。此时可以通过鼠标进行选择。
2)选择OS 部署,点击“部署OS ”,下一步;
3)选择部署路径,点击“直接转至OS 部署”,下一步;大概10秒钟后系统界面跳转到下一步骤。
4)选择操作系统,“Microsoft Windows Server 2008 x86 with SP2”,下一步;
3-4 操作系统选择界面
5)系统提示自动编写操作系统驱动程序,此时需等候不到5分钟的时间,自动完成后进入安装选择模式,选择“手动安装”,点击下一步;
6)选择引导模式,选择“BIOS ”,点击下一步;
7)此时,系统提示插入操作系统介质,把系统安装光盘放入光驱内,点击下一步;
3-5 插入介质提示界面
8)重新引导系统,完成。
3.3 安装系统
OS 部署完成后,系统自动重启,进入到系统配置中,此时可以开始对系统硬盘进行分区等操作配置。
1)确定输入语言和其他首选项,然后单击“下一步”继续。
2)开始安装,选择操作系统“Microsoft Windows Server 2008 Enterprise”,点击“下一步”。
3)对磁盘点击“新建”划分分区,不同磁盘大小划分不同的规格,如下表:
磁盘大小划分表
4)对所有已划分的盘符进行格式化,最后在分区1中点击“下一步”进行操作系统的安装。
3-6 系统分区界面
5)操作系统安装需等候40分钟左右的时间,期间系统会重启2到3次,属正常情况,系统安装完成后,要求新建用户密码,此时可根据要求输入密码(Admin123)。
6)至此,戴尔R720服务器操作系统安装到此结束。
范文二:安装戴尔服务器、存..
服务说明
安装戴尔服务器、存储或外围设备
服务 SKU
见附录 A 。
服务概览
本服务提供用于以下新增或现有戴尔产品之一的物理安装和开机:
? 服务器,如 Dell PowerEdge? 服务器、 PowerVault? 网络连接存储 (
? 存储设备,如 Dell PowerVault或 Dell EqualLogic? 盘柜;或
? 外围设备,如键盘视频鼠标 (
将(“ 受支持的产品 ” )安装到戴尔支持的机架或独立装置中,此服务说明(“ 服务 ” )中做了详细规定。 本服务包括安装至戴尔 支持的机架中、连接客户提供的线缆,以及在必要时安装客户提供的戴尔配电装置 (
除非在附录 B 中另有说明,否则本服务的提供时间是正常的戴尔工作时间(周一到周五 8:00 AM到 6:00 PM,客户当地时 间)。 在非正常的戴尔工作时间提供的任何服务均将另行收费,并反映在客户发票中。 除非销售团队和戴尔项目经理另有 安排,否则在当地、省 /自治区 /直辖市和 /或国家和地区节假日内不会进行任何服务活动。
关键服务步骤
? 现有的受支持的产品(卸载):
1. 确保客户已正确将受支持的产品关机。
2. 从机架中卸下受支持的产品。
3. 从机架中卸下与机架相关的硬件(例如滑轨、支架和托架)。
4. 检查零件是否有损坏。
? 受支持的产品(服务器、存储或外围设备)的安装:
1. 打开新的受支持产品的包装,并在安装之前检查所有硬件。
2. 安装受支持的产品:
a. 对于桌面安装:
i. 将受支持的产品放置在客户指定的位置。
ii. 将电源电缆连接到客户提供的电源插座。
b. 对于机架安装:
i. 将与机架相关的硬件(例如滑轨、支架和托架)安装到机架上。
ii. 如有必要,从受支持的产品中卸下部件(例如刀片式服务器、电源和驱动器),从而减轻整体提起重量,以 便于安装。
iii. 将受支持的产品安装到机架中。
iv. 重新安装在上述步骤中卸下的所有部件。
v. 必要时将客户提供的戴尔品牌 PDU 安装到机架上,从而为受支持的产品配置适合的电源。
vi. 安装电源线并对其进行布线以连接至受支持的产品。
3. 对于 PowerEdge 刀片式服务器盘柜,安装随盘柜附带的任何刀片式服务器:
a. 如有必要,关闭盘柜的电源。
?2010 Dell Inc.
b. 从盘柜的插槽中卸下任何空位挡板。
c. 将刀片式服务器插入盘柜的插槽。
4. 必要时将客户提供的电缆连接到受支持的产品(例如网络、键盘、鼠标和视频)。
5. 根据客户请求,将客户提供的预打印标签(最多 10个)附加到电缆或受支持的产品中。
6. 以有序方式对电缆进行组织、分组和捆绑,以便于访问受支持的产品。
7. 对于存储或外围设备,安装随存储购买的任何必要的主机适配器卡,并在卡与设备之间连接任何互联电缆。
8. 接通受支持产品的电源,执行初始系统引导,并确保故障指示灯未亮起。
9. 如果存储或外围设备配有网络管理功能,请根据客户提供的参数配置网络内部协议 (
10. 将所有包装材料移至安装位置附近(10米以内)客户指定的地方,或与客户商定由客户将其移走。
本服务不包括
? 修改非戴尔机架,使其允许在其中安装新的受支持产品。
? 安装外接至机架的线缆。
? 安装或配置任何软件。
? 数据或应用程序的任何迁移。
? 重新调整现有机架内的其他组件的位置。
? 从不受支持的机架中卸下任何产品或将任何产品安装到其中。
? 对客户提供的与受支持产品无关的任何线缆进行布线。
? 任何标签或标签打印。
? 配置任何刀片式服务器输入 /输出 (
? 任何未在本服务说明中特别注明的活动。
客户责任
? 授予访问权限。 客户表示并保证已获得相关许可,允许客户与戴尔为提供这些服务而访问和使用受支持产品、产品中的 数据以及产品中包括的所有硬件和软件组件。 如果客户尚未获得此许可,则有责任在要求戴尔执行这些服务之前获得此 许可(费用由客户自行承担)。
? 与电话分析师和现场技术人员合作。 客户同意与戴尔电话分析师及其现场技术人员合作,并遵照其指令行事。 经验表 明,通过用户与技术人员的密切合作,大多数系统故障和错误均能通过电话修复。
? 受支持发行版本。 客户必须按照戴尔指定的最低版本等级或配置(如 PowerLink[针对 Dell | EMC存储设备 ]或
[针对受支持产品 ]上所指定)维护软件和受支持产品。 客户还必须按照戴尔的指示安装补救性的更换 部件、补丁程序、软件更新或后续版本,以保证受支持系统有资格享受本服务。
? 第三方保修。 这些服务可能需要戴尔访问非戴尔制造的硬件或软件。 如果由戴尔或制造商以外的任何其他人处理该硬件 或软件,某些制造商的保修可能会失效。 客户有责任确保戴尔执行服务不会影响此类保修,或者客户可以接受戴尔执行 服务对此产生的影响。 对于第三方保修或戴尔服务对这些保修造成的影响,戴尔不承担任何责任。
? 现场义务。 当需要在现场执行服务时,客户必须为戴尔提供访问其设施和受支持产品的免费、安全和充分的权限。 充分 的访问权限包括充足的工作空间、电力及本地电话线路。 如果系统不包括,还需要提供监视器或显示器、鼠标(或指点 设备)和键盘(戴尔不为此付费)。
? 将受支持产品置于机架内的即时安装区域。
? 确保所需的电源插座已安装并且可正常工作。
? 根据需要提供戴尔 PDU ,以便对受支持产品正确通电。
? 提供为了实现受支持产品的功能所需要的所有其他线缆。
? 提供预打印的标签,以便根据请求标记受支持产品或任何附加线缆。
? 根据请求提供除了戴尔提供的标准塑料绑线带外的任何绑线带。
? 处理包装材料和其他碎片。
客户数据备份责任
在开始提供本服务之前,完成对所有受影响系统中现有的全部数据和程序的备份。 对于因戴尔或第三方服务提供商的服务、 支持或任何作为或不作为(包括疏忽)导致的数据或程序的丢失或恢复或者无法使用系统,戴尔概不负责。
?2010 Dell Inc.
条款和条件概览
本协议(下称 “ 协议 ” 或 “ 服务说明 ” )由客户(下称 “ 您 ” 或 “ 客户 ” )与客户发票上指明的戴尔实体签署。 如果客户通过转销商或 经销商购买本服务,销售的最终价格以及条款和条件将在客户和第三方(客户从其处购买服务)之间达成协定;不过,此处 所述条款适用于您使用戴尔提供的服务和服务性能。 从戴尔购买这些服务(如本文档中所定义),即表示客户同意接受本文 档中规定的所有条款和条件的制约。 客户同意,在初始期限到期后对服务的续订、修改、延长期限或继续使用应遵守当时的 服务说明,可从 www.Dell.com/ServiceContracts查看该服务说明。
本服务根据客户与戴尔单独签署的主服务协议(如果没有此类协议,可从 www.Dell.com/ServiceContracts上获取戴尔的标准客 户主服务协议 (
其他重要信息
A. 转让。 戴尔可将本服务和 /或服务说明分配给合格的第三方服务提供商。
B. 取消。 根据适用于客户所在地理位置的产品和服务退货政策,客户可在收到受支持产品后的规定天数内,通过向戴尔提交 书面取消通知终止本服务。 如果客户在该期限内取消本服务,则戴尔会在扣除本服务说明中规定的支持声明费用(如果 有)后将款项全额退回客户。 但如果客户收到受支持产品的天数已超过此规定期限,则不能取消本服务,然而国家和地区 /省 /自治区 /直辖市有本协议须遵守的适用法律的情况除外。
出于以下任何原因,戴尔可在服务期限内随时取消本服务:
? 客户未能按照发票条款支付本服务的总费用;
? 客户拒绝与提供帮助的分析师或现场技术人员合作;或
? 客户未能遵守本服务说明中规定的所有条款和条件。
如果戴尔要取消本服务,会按照客户发票上指明的地址向客户发出书面取消通知。 通知中将包括取消的原因以及取消的生效日 期,一般自戴尔向客户发出取消通知十 (10)天以后开始生效,除非国家和地区法律规定了本协议须遵守的其他取消条款。 如果戴 尔依照本条款取消本服务,客户不会获得已向或应向戴尔支付费用的任何退款。
C. 支持限制。 如果因戴尔无法控制的任何原因造成无法履行服务或服务延迟,戴尔概不负责。 本服务仅适用于按照受支持产 品的设计用途进行的使用。
D. 服务部件的所有权。 所有从受支持产品上卸下并退回戴尔的戴尔服务部件均归戴尔所有。 客户收到戴尔提供的更换部件 后,如果要保留从系统中卸下的任何服务部件(享有保留您的硬盘服务的系统中的硬盘除外),须按部件的当前零售价向戴 尔付款。 对产品进行保修维修时,戴尔可以使用由不同制造商制造的全新或经过维修的部件。
E. 可选服务。 客户可从戴尔购买的可选服务(包括按需支持服务、安装服务、咨询服务、受管服务、专业服务、支持服务或 培训服务),这些服务可能因客户位置的不同有所差异。 购买可选服务可能需要与戴尔签署单独协议。 如果没有此类协 议,将会根据本协议提供可选服务。
F. 期限和续订。 客户将在戴尔出具的发票上指明的期限内享受服务。 在服务期限到期前,客户可根据当时有效的可用选项并 遵循戴尔在当时的相关程序延长服务期限。
此外,戴尔可选择通过向客户发出用于续订服务的发票,来做出服务续订建议。 客户可选择(在法律许可的情况下)在到期日前 支付此类发票,以表示同意此类续订服务。 支付续订发票即表示客户同意延长本服务的期限。 客户续订本服务,即表示同意在 续订期间遵守当时的条款。 如果客户选择不支付续订发票,服务会在客户初始或最后一次所支付发票上规定的到期日终止。
G. 地理限制和地址变更。 本服务将交付到客户发票上指明的地点。 本服务并非在所有地点都提供。 服务选项(包括服务级 别、技术支持时间和上门响应时间)因地理位置而异,并且客户所在地区可能不提供某些选项。 对于地址已变更的受支持产 品,戴尔向其提供服务的义务取决于当地服务的可用性,并且可能会另行收取费用;此外,戴尔可能会对地址已变更的受支 持产品进行检测和重新认证,并按照戴尔当时的时间和材料咨询费率收费。 客户应免费为戴尔提供对其设施的充分且安全 的访问权限,以便戴尔履行其义务。
?2010 Dell Inc.
PowerVault 、 PowerEdge 、 PowerConnect 和 EqualLogic 是 Dell, Inc.的商标。
?2010 Dell Inc.
Appendix A Service SKUs
?2010 Dell Inc.
?2010 Dell Inc.
?2010 Dell Inc.
附录 B
戴尔工作时间的例外情况
?2010 Dell Inc.
范文三:DELL机架式服务器导轨安装图释
Server Depth w/ CMA Rail Compressed Rail Extended
1950 Sliding Rapid \ VersaRail 26.98 inch 29.5 inch
2950 Sliding Rapid \ VersaRail 26.84 inch 29.46 inch
Rail Conversion
The following procedure outlines converting the 9th generation PowerEdge
rails from RapidRails to VersaRails. Converting from VersaRails to RapidRails follows the same procedure.
NOTE:
The rail in the example is a PowerEdge 1950 rail. The PowerEdge 2950
rails follow the exact same conversion process.
9th Generation Rail Conversion
1. Locate the rail conversion bracket on the end of the rail.
2. Lift the release lever on the rotating mounting bracket.
9th Generation Rail Conversion
3. Rotate the bracket counter clock wise.
4. Lift the bracket and rotate it 180 degrees counter clock wise.
9th Generation Rail Conversion
9th Generation Rail Conversion
5. Line the bracket up with the two posts and set it down.
9th Generation Rail Conversion
6. Rotate the bracket clock wise until it snaps into place.
9th Generation Rail Conversion
Racking
The following procedure outlines the process of racking the PowerEdge 2950 using the new 9th generation PowerEdge rails.
Racking the PowerEdge 2950
1. Push the front slide assembly mounting hook into the square hole
on the vertical rail.
Racking the PowerEdge 2950
2. Push the rear slide assembly mounting hook into the square hole
on the vertical rail.
3. Repeat steps 1 and 2 for the slide assembly on the other side.
Racking the PowerEdge 2950
4. Extend the inner member rails out of the rack.
5. Align the server's shoulder nuts with the rail's J-slots.
6. Lower the server into the rails making sure the all shoulder nuts
slide into the rail j-slots.
Racking the PowerEdge 2950
7. Gently push the server towards the back of the rack to engage the
j-slot locking levers.
8. Press the slide-release latch on the outside of each inner slide.
9. Push the server towards the back of the rack.
Racking the PowerEdge 2950
10. Tighten the ear nuts to secure the server to the rack.
范文四:戴尔 DELL服务器的操作系统安装方法
戴尔 DELL服务器的操作系统安装方法
注意:采用DOSA光盘引导和安装服务器系统,将使您服务器硬盘上的所有数据丢失,因此此方法仅供全新的服务器和确认数据有备份前提下的服务器安装
此安装方式仅支持零售版操作系统,如果是盗版光盘,如市面上常见的WINDOWS2003 3IN1版本则无法使用(DELL强烈建议您采用正版软件)
安装前请确认您的服务器光驱为DVD
首先,将随机配送的Systems Management Tools and Documentation version6.0光盘放入服务器光驱,将服务器设置为光驱引导。
注:此版本dosa支持相应系统为:
1、Server 2003 sp2 ; 2、Server 2003 sp2 64 bit ; 3、windows 2003 SBS sp2; 4、Server 2008; 5、windows 2008 SBS\EBS x64; 6、Red hat Linux4.7 32bit; 7、Red hat Linux 4.7 64bit; 8、Red hat Linux5.2 32bit; 9、Red hat Linux 5.2 64bit; 10、Suse Linux10 sp2 64bit; 11、ESX 3.5 U4
操作系统光盘版本一定要和DOSA 安装时选择的版本一致,否则DOSA会报告插入无效光盘。
支持的服务器类型:
PowerEdge M610
PowerEdge M710
PowerEdge R610
PowerEdge R710
PowerEdge T610
PowerEdge T710
PowerEdge R410
PowerEdge T410
DOSA6.0 下载地址:
http://support.dell.com/support/downloads/download.aspx?c=us&l=en&s=gen&releaseid=R21537
6&SystemID=pwe_r710&servicetag=CLQRN2X&os=WNET&osl=en&deviceid=17861&devlib=0&typecnt=0&verc
nt=1&catid=-1&impid=-1&formatcnt=1&libid=36&fileid=305539
稍等片刻,屏幕出现如下界面(不同版本的DOSA光盘界面可能略有不同,但所有步骤一样)
引导光碟将检测您的服务器硬件,这里需要5分钟左右,请耐心等待。
选择简体中文:
接受协议:
出现安装画面,单击:“服务器操作系统安装”
第一步:请将时区设置为:北京,香港,重庆,乌鲁木齐
第二步:选择您要安装的操作系统
第三步:确认出厂有做好raid,选择跳过raid配置
第四步:引导分区大小为C盘大小,请根据自己的要求设置足够。
第五步:可以跳过此设置,网络配置可以等系统安装完成后再进行配置(DELL提醒您安装操作系统时请拔除网线,待打好系统补丁后再插上网线,以防止病毒入侵)
第六步:本页可以默认不更改继续下一步。
ProductID为您所购买的操作系统的安装系列号
请勿选择加入域,除非您请出您的网络环境为域环境,并且您知道您的域环境设置,否则请安装完系统后请你公司的IT部门设置
第七步:确认安装摘要后,弹出CD已选中,然后选择继续。
第八步:请将 系统光盘 插入,放入您的操作系统光盘,文件复制将开始,如果提示复制错误或者光
盘错误,请更换你的系统光盘
注:此版本dosa支持相应系统为:
1、Server 2003 sp2 ; 2、Server 2003 sp2 64 bit ; 3、windows 2003 SBS sp2; 4、Server 2008; 5、windows 2008 SBS\EBS x64; 6、Red hat Linux4.7 32bit; 7、Red hat Linux 4.7 64bit; 8、Red hat Linux5.2 32bit; 9、Red hat Linux 5.2 64bit; 10、Suse Linux10 sp2 64bit; 11、ESX 3.5 U4
操作系统光盘版本一定要和DOSA 安装时选择的版本一致,否则DOSA会报告插入无效光盘。
安装步骤:
1、在开机自检时按F10 进入dosa 安装界面:
2、进入F10界面,这里需要耐心等待5分钟左右:
3、进入安装界面选择os deployment:
4、配置raid (在raid卡bios 中也可进行配置,这里就可以选择跳过raid 配置):注:重新配置
raid 会格式化硬盘如果确定要配置一定要备份好数据。
Raid 配置界面:
(1):现有的raid 配置,如果需要重新设置可选下一步:
(2):确认raid卡型号,点击下一步:
(3):可以选择高级或快速配置:(本文选择快速向导)
(4):选择要配置的raid 级别:
(5):raid 配置完成
5:确认要安装的系统,选择下一步:
读取文件需要一些时间:
6:确认放入系统盘
注意会有以下界面提示(截图是中文的),意思是USC安装会创建临时的闪存分区,占用盘符C,请确
认将系统安装在正确的盘符C上,关于分区盘符的问题,请参考微软KB。
7:点击完成重启机器
8、进入windows 安装界面:(让其自动引导不需要按F6)
9:识别到硬盘
有可能盘符C会被临时闪盘占用,按照下面方法操作:
在本地启动硬盘上创建新分区,盘符自动分配成F或其他盘符:
把刚创建的分区F:删除, 看到盘符C:被释放出来。
再在本地启动硬盘上创建新的分区,就自动分配盘符C:了。
如果这样操作盘符C还是不能释放出来,创建一个F:盘,然后不格式化,强制重启,重新自检分配盘符就会正常了。
如果强行重启还不能解决,就只有初始化虚拟磁盘了,(注意:数据全部丢失,无法恢复。只针对于新机器,之前安装没有正常完成或退出的情况。使用中的机器,如果有数据,请联系工程师)
10、将光标移动到未指派分区按C 创建分区:(默认为所有的容量,需要手动更改建议C盘20G)
11:将光标移动到C盘位置选择回车进行安装,选择NTFS快速格式化:
13:文件复制完成重启后进入系统:
14、至此2003安装完成。
范文五:戴尔服务器安装及验收标准
设备安装调试总体计划
设备装调总体计划包含两个方面:其中之一是安装调试进度计划;另一个是安装调试过程计划。
对于安装调试进度,我们依据本次项目总体进度要求,在规定时限内完成山东省所有地市的网络设备的安装调试及网管软件的安装调试,实现系统的试运行。
安装调试过程计划包含对于具体实施环节、具体设备的实施计划,在制定系统设备的安装调试计划时,由专门的技术人员和省厅信息部门的业务人员一起制定软硬件系统的测试计划。
设备安装调试总体原则
本项目所涉及的设备安装调试要遵守IT设备装调的一般性原则,同时由于应用的特殊性,还要遵循在施工的特殊原则。
完备的装调准备——在设备装调前,由公司技术管理人员派发设备装调任务;
装调方案审议——对于不同的设备,由工程师制定相应的装调步骤方案、参数设置方案等,由项目经理和相关实施人员共同讨论,分析设备装调的具体细节和实施难点;
装调的专业性——严格控制设备装调的参与人员,杜绝非技术人员单独操作;
装调的程序性——详细记录设备装调报告,记录装调问题以便及时解决和备案。
设备安装调试准备工作
设备装调的前期要进行充分的准备,在本项目设备装调的准备工作主要有设备的测试准备、全部设备的编码分类统计工作。
项目涉及的主要设备有:
(1) 服务器、存储等;
(2) 各环节所使用的通讯设备如协议转换机;
考虑到在本项目中会涉及大量设备,为了统一管理和系统实施及维护的便利性,我们建议对网络设备进行统一编码,建立设备档案。使用设备全名的汉语拼音字头、设备所属机构代码、设备类别等进行混合编码,同时在设备编码对照表中附加设备产品序列号字段、设备装调工程师字段、设备维护描述字段等辅助信息。这样可以方便的从编码表中定位设备品名、设备的物理位置、设备使用情况等重要信息,既方便了系统的运营维护、又对本项目的设备管理提供了具体的有
益的帮助。
测试验收方案
测试概述
为了确保工程顺利完工,在设备安装调试完成之后,业务正式切换到网络之前,项目组将组织验收测试工作。
验收目标
, 确认设备硬件的可用性
由于高端设备已经在出厂之前的厂验中已经连续运行拷机测试,在本次验收中通过设备上电验收,可以进一步确保硬件的可用性。
, 确认软件功能的稳定性
通过设备连续运行与拷机,确认所有设备的软件均没有出现任务退出、异常重起等严重故障,确认所有设备的软件稳定性。
, 进一步验证总体设计及实施方案的正确性
在验收过程中对方案的正确性和完备性进行进一步的验证
, 增进用户对设备的了解
通过硬件安装及软件测试,使用户对产品及整个组网方案有详细和系统了解,以方便了日后的使用和维护。
验收内容
本次验收主要包括如下内容:
, 硬件验收
包括所有设备的开机自检及硬件信息检验。
, 连通测试
针对所有已安装设备下进行PING操作,并记录时延和丢包率。
, 网管功能与性能
在实际网络环境中,测试网管的功能和性能。
, 系统测试
在实际网络环境中,对各节点的CPU、内存使用情况进行检查。对各节点保存的日志信息进行检查分析。对整网路由协议状态进行检查确认。对整网的路由容量和标签容量进行分析。
验收对象
本次验收范围为项目中涉及到的所有设备。
测试项目
, 单机软硬件验收
, 系统上电验收
测试目的 验证设备系统经过运输后是否正常上电,是否正常启动 测试对象 本项目中涉及的网络设备
预置条件 1.设备Console口与终端计算机串口连接正确。
2(启动计算机的Windows操作系统,进入超级终端,设置连接参数:波
特率为9600bps,无奇偶校验,8位数据位,1位停止位,无流控。
3(终端仿真类型设为VT100或自动检测。
4(功能键、箭头键和Ctrl键的类型设置为终端键类型。 测试过程 1( 确认插座连接无误,打开电源开关。
2( 观察超级终端控制台上显示信息有无报错现象。
3( 观察系统和电源指示灯是否表示正常。风扇是否正常运转。 测试结果
结论
, 软硬件信息检查
测试目的 检查并记录SAT1种设备软硬件信息,软件版本是否满足需求,硬件是否
符合合同供货内容。
测试对象 本项目中涉及的网络设备
预置条件 1(系统上电正常,设备启动正常;
服务器等设备可以正常启动无报警灯亮,查看设备相关软硬件信息。 测试过程
测试结果
结论
, 连通性测试
, Ping延时测试
测试目的 测试各业务路径延时。
测试对象 本项目中涉及的网络设备
预置条件 1(系统上电正常,设备启动正常;
2(完成工程实施及初调
分别选定设备,执行PING操作,记录各路径下的PING延时。 测试过程
测试结果
结论
, 系统测试
, CPU占用率检查
测试目的 测试各节点在实际网络中CPU使用率情况 测试对象 本项目中涉及的网络设备
预置条件 1(系统上电正常,设备启动正常;
2(完成工程实施及初调
查看并记录各节点CPU占用率。 测试过程
测试结果
结论
, 内存使用检查
测试目的 测试各节点在实际使用中内存使用率情况
测试对象 本项目中涉及的网络设备 预置条件 1(系统上电正常,设备启动正常;
2(完成工程实施及初调
查看并记录各节点内存使用率。 测试过程
测试结果
结论
, 日志信息检查
测试目的 在实际网络运行情况下,对各节点保存的日志信息进行检查分析。
测试对象 本项目中涉及的设备
预置条件 1(系统上电正常,设备启动正常;
2(网络实施及调试已经完成。
收集log信息,并进行分析。 测试过程
测试结果
结论
15.7.2.3验收结论
验 收
概
述
甲
方
结
论
甲方技术部门签章 乙方签章
经办人 经办人
日 期 日 期
转载请注明出处范文大全网 » 戴尔R720服务器安装步骤