范文一:QSM11电器接线图
RED DC VOLTAGE BLUE INPUT SIGNALS BLACK GROUNDS, SHIELDS AND RETURNS PURPLE OUTPUT SIGNAL GREEN DATA LINKS 22 1 MULTIPLE UNIT 31 2SYNCHRONIZATION 3IDENTIFICATION 32 4 SWITCH 19 MULTIPLE UNIT 11 A SYNCHRONIZATION 22REMOTE BIDENTIFICATION 21 33THROTTLE SHORTING PLUGS 4 4 C REMOTE 43 BTHROTTLE A 20 SWITCH 48 C 5 C 47 BA3 49 A B4 D03 2 CE 6 13 B F 1 A 09
11
B TACHOMETER U 35 IDLE SHUTDOWN RELAY L 10 K H ALTERNATE TORQUE SWITCH 02 E 01 ALTERNATE GOVERNOR SWITCH A D 25 33 INTERMEDIATE SPEED CONTROL 23 SWITCH ALTERNATE IDLE 45 C 14 O INCREMENT / DECREMENT N 24 ALTERNATE N DROOP 41 SWITCH E C MULTIPLE UNIT 34 ON/OFF T 42 O ENGINE 12 PROTECTION R DIAGNOSTIC / USER-ENGAGED 44 SNAPSHOT ON/OFF MANUAL 15 FAN ON/OFF 06 ENGINE STOP LAMP (RED) 16 ENGINE WARNING LAMP (YELLOW)
05 MAINTENANCE LAMP
WAIT TO START LAMP 04
38
29
30
39
40
50
18
28
07
08
17
A
B
46 C D 37 B E C 36 A F 26 G 27
B C A
REV 8/19/02 PAGE 1 of 2
SWITCHED OUTPUT A SHORTING PLUG SWITCHED OUTPUT A OEM PRESSURE +5 VOLT SUPPLY CONNECTOR 1A1 OEM PRESSURE SIGNAL 3C3OEM PRESSURE RETURN 2B 2SWITCHED OUTPUT A 55SPARE 66SWITCHED OUTPUT A 4 4
ALTERNATE TORQUE CURVE SELECT 2 INPUT
OPTIONAL 2-WIRE ACOOLANT LEVEL SENSOR B 31 PIN-OEM CONNECTOR
OPTIONAL COOLANT ALEVEL MODULE BFOR 2-WIRE SENSOR
30 C
OEM TEMPERATURE D SENSOR OEM TEMPERATURE INPUT E A04OEM TEMPERATURE RETURN B 03
05DA06COOLANT LEVEL CSENSOR 07B 19
31 OEM SWITCH
D COOLANT LEVEL A SENSOR SHORTING C SWITCHED JUMPERS OUTPUT A B SOLENOID SWITCHED OUTPUT B 27SOLENOID
28
08PWM DEDICATED OUTPUT 09GRID HEATER 10SOLENOID 11
12AFAN CLUTCH RELAY B 13
17AIR CONDITIONER PRESSURE SWITCH 18
MAGNETIC SHAFT SPEED (+) PICKUP SHAFT A21SPEED SENSOR SHAFT SPEED (-) B 22
FREQUENCY (+) THROTTLE 16 (-)
FUSE 2A
REV 8/19/02 PAGE 2 of 2
范文二:安全继电器接线图
Emergency Stop Relays, Safety Gate Monitors
Category 4, EN 954-1
PNOZ X3
Technical Details PNOZ X3 Electrical Data Supply Voltage AC: 24, 42, 48, 110, 115, 120, 230, 240 V
DC: 24 V 85 ... 110 % Tolerance
Power Consumption Approx.2.5 W/5 VA
Voltage and Current at the Input and 24 VDC, 35 mA
Reset Circuits and Feedback Control Loop
Switching Capability in accordance with
EN 60947-4-1, 10/91 AC1: 240 V/8 A/2000 VA DC1: 24 V/8 A/200 W EN 60947-5-1, 10/91 AC15: 230 V/5 A; DC13: 24 V/6A
(DC13: 6 cycles/min.)
Output Contacts 3 safety contacts (N/O),
1 auxiliary contact (N/C)
Contact Fuse Protection 10 A quick or 6 A slow Emergency stop relay and safety
(EN 60947-5-1, 10/91) gate monitor in accordance with
VDE 0113, 11/98, EN 60204-1, 12/97 Semiconductor Outputs 24 VDC/20 mA, short-circuit protected and IEC 204-1, 11/98, safety External Supply Voltage 24 VDC ?20 % component in accordance with the Times Lift Directive 95/16/EC and EN 81-1/ Delay-on Energisation Monitored manual reset: max. 100 ms 1998 Auto./ manual reset: max. 0.3 s Delay-on De-energisation With E-STOP: max. 80 ms With power failure: max. 1 s Features Recovery Time Approx. 1 s Simultaneity channel 1/2 , q Monitored manual or automatic Max. Supply Interruption before De-energisation Approx. 25 ms reset can be selected Environmental Data q 1 semiconductor output (K1/K2) Ambient Temperature -25 ... +55 ?C q Each AC unit can be operated Mechanical Data with 24 VDC Maximum Cross Section of 2 x 1.5 mm2 or 1 x 2.5 mm2 q Safety gate function with External Conductors Single-core or multi-core N/C-N/O combination with crimp connectors q Only dual-channel operation will Dimensions (H x W x D) 87 x 45 x 121 mm detect shorts across the input
Weight 420 g contacts
Description Operating Modes Approvals
q q 45 mm, P-93 housing, DIN-Rail Single-channel operation
q Dual-channel operation mounting PNOZ X3 q Automatic reset q Positive-guided relay outputs: q Monitored manual reset – 3 safety contacts (N/O) q – 1 auxiliary contact (N/C) q Connections for – E-STOP button q – safety gate limit switch – reset button q q Semiconductor output signals
ready for operation q LEDs for channel 1, channel 2 and q power q Increase in the number of safety contacts available by
connecting expander modules.
Pilz GmbH & Co., Felix-Wankel-Stra?e 2, 73760 Ostfildern, Deutschland NSG-D-2-036-07/00 Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
Emergency Stop Relays, Safety Gate Monitors
Category 4, EN 954-1
PNOZ X3
Internal Wiring Diagram q Example 5
Dual-channel safety gate control with
monitored manual reset. Auxiliary Safety contact Reset circuit Input circuit contacts UB A1 A2 S33 S34 S14 S13 S11 S12 S31 S32 13 23 33 41 S33 S21 S11 AC S1 DC S22 K1 S3 + S31 B1 Start CH2 CH1 - S2 B2 Unit
K2 Y31
S32 S12 S34 Y32 &
q Example 6
Dual-channel safety gate control with S21 S22 14 24 34 42 Input circuit automatic reset.
S13 S11 S21 External Wiring
S1
q Example 3 q Example 1 S22 Dual-channel E-STOP wiring with S31 Single-channel E-STOP wiring with monitored manual reset. automatic reset. S2 S21 S31 S11 S33 S11 S31 S21 S13 S12 S32 S14 S1 S1 – Key S3
S1/2: E-STOP or safety gate switch
S3: Reset button S12 S32 S22 S14 S22 S32 S12 S34 Switch operated
q Example 2 q Example 4 Gate open Single-channel safety gate control Single-channel E-STOP wiring with monitored manual reset. with monitored manual reset. Gate closed
S11 S31 S21 S33 S11 S21 S31 S33 S1 S1 S3 S3
S12 S32 S22 S34 S34 S12 S22 S32
Pilz GmbH & Co., Felix-Wankel-Stra?e 2, 73760 Ostfildern, Deutschland NSG-D-2-036-07/00Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
Emergency Stop Relays, Safety Gate Monitors
Category 4, EN 954-1
PNOZ X3
q Increase in safety contacts
The number of output contacts can
be increased by using expander
modules or relays/contactors with
positive-guided contacts.
– Ooperation with automatic reset.
1L1 K6
K5 S13 S14 13 14
K5 K6
1L2
– Operation with monitored manual reset.
1L1
K6 S3 K5 S33 S34 13 14
K5 K6 1L2
Pilz GmbH & Co., Felix-Wankel-Stra?e 2, 73760 Ostfildern, Deutschland NSG-D-2-036-07/00 Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
范文三:继电器接线图
AMX 系统接线说明
1. 首先,AMX设备需要控制其他设备,所以它自身必须是常给电的。因此,AMX主机和
强电继电器箱必须常给电。
2.对于早期的
AMX设备,采用的是AXLINX总线,则可以用四芯的线缆将设备进行连
接,AXLINX插头上PWR为电源,GND为地 ,AXP和AXM传输数据.连接方式不限.可采用串联,并联,及串并联混合式.连接只要注意每针脚一一对应即可.如图1.(注意:AXLINX总线的最终连接长度加起来不能超过1000米,如果超过,需要另外加一个设备AXB-MPE来扩展总线长度)
图1.AXLINX总线连接图
3.对于继电器箱的连接上,我们采用的是弱电继电器控制强电继电器,可同时参看图2和图3
首先从AMX主机控制RELAY口上接出8+1芯的控制线.用AMX随机提供的短铁片将AMX弱电继电器的A端或B端(任选一端)串接,做为他们的公共端,连接8+1控制线的1芯,另一端接强电继电器箱的P3位置COM口.(如图3.)8芯线连接AMX主机的一端接A端或B端(如果公共端选的是A端,则接B端,反之,则选A端),另一端连接到强电继电器箱上,注意一一对
应,例如,AMX主机上从一号RELAY口接出的线接到强电的继电器箱上的一号控制端口上.
图2.AMX系统继电器连接原理图
电动幕窗帘示意连接图
灯光窗帘示意连接图
零线
AC 220V
火线
主机后RELAYS接口连线
主机后RELAYS接口连线
图3. NP-REL8强电继电器箱示意图
4.强电继电器箱的内部接法:(以NP-REL8为例)首先,整个NP-REL8的继电器箱需要220伏
交流电的常给电,在其右下方有一排接线端子(N和L),其中最右端L的为火线进线端子,另N为零线端子.(1)如果控制的是灯光或电源等开关量的设备,可以采用进线火接L,出线火接NO的接法,零线压在公用的6个零线端.如图.如果AMX主机给出一个弱电吸合信号,那么强电继电器就会吸合,这样L端就和NO端导通,灯光就亮了.(2)如果控制的是电动幕,窗帘,升降机等类似产品,为了保证电动幕的升,降,停三个状态都能正常运作,就必须采用两路继电器控制.如图.2,首先,将1#继电器NO和2#继电器的L端相连接,电动幕的火线进线接1#继电器L端,2#继电器的NO和NC分别端接电动幕的上升和下降火线.当1#继电器吸合、2#继电器断开,电动幕上升,1#和2#继电器都吸合,电动幕下降,1#和2#继电器都断开或只断开1#继电器电动幕停止.这样就保证了电机不会因为上升和下降的火线同时有电而烧毁.
(附注:REL1、REL2…REL8为强电继电器接口,每一接口有三个接线端,分别为 : “NC” -- 代表常闭端,继电器 时与 “L” 连通 “NO” -- 代表常开端,继电器 被触动 时与 “L” 连通 “L” -- 代表输入端)
上面两图为继电器连接示意图:
5.串口设备部分(RS232):AMX端需要的是一个DB9针母头串口.2---接收针,3---发送针,5---地
.
一般的232标准:
公头------公头或母头-----母头 公头-----母头 2------3 2------2 3------2 3------3 5------5 5------5
一般的422标准:
4,6并起来接“+”或“A”;1,9并起来接“-”或“B”;5接地
一般的485标准:
4,6并起来接“+”或“A”;1,9并起来接“-”或“B”;5接地
但是许多串口设备有自己的针脚定义标准,需要查看被控设备说明书每一个针脚的定义.详情请参阅被控串口设备说明书.
6.对于一些新的AMX设备,AMX除了提供AXLINK连接方式外,还提供ICSNET总线结构
的连接方式,ICSNET连线方式采用的是标准5类线,连接方式只需要将网线的两端都压制成相同的线序格式(如586-A或586-B)注意: 不可以把ICSNET总线和普通的网线HUB连接,因为ICSNET总线是AMX自己开发的一种数据传输方式,非TCP/IP协议,其中有两芯是有弱电电压的,混接有可能导致HUB烧毁
.
网
7.AXB-VOL3 3频道音频控制器
功能:可以将三个独立通道的音量分成128段,并可通过控制界面将其分别调至任意的大小,使用起来就想一个调音台一样。当调节任意通道时其设备都会有相应的指示灯表示。
前面板:
AXLink绿色:系统指示灯(电源指示)。其闪烁频率与主控机相同。
1、2、3通道红灯:如果任意通道处于被调节状态,其对应的指示灯就会闪烁。如其处于静音状态其指示灯会常亮。
8位二进字地址码开关:设制设备的设备号。
通道号=所被拨至ON的位置所有开关代表的值的总合,设备号在AXCESS程序里面必须和其它设备号相匹配。
其设备后有AXLink连接插口与中控后面的插口相连接,其连接方法如下:
网
设备后面板有三路音频通道,每一路均有输入输出连接凋端口,其连接方法如下:
非平衡接法 平衡接法(如果需要的话可以选择600欧姆电阻)
8.灯光连接法:
设备与其它拓展设备一样有着AXLink连接插口与中控后面的插口相连接,其连接方法如下:
8位二进字地址码开关:设制设备的通道号码。
用Axlink DIP设置RDD-DM4的Axlink设备号为1-255,设备号在AXCESS程序里面必须和其它设备号相匹配。
用
PROlink DIP设置(地址号为1-10)控制RDD-DM4
网址:http://www.nanpeng-tech.com
灯光控制接法
范文四:相序继电器接线图
相序保护继电器有四大类产品,分别是三相相序用于监测三相电源(包括相序、缺相、欠压、过压、相不平衡等),从而保护电机及其它装置。
具体接线图如下:
6.jpg (57.55 KB, 下载次数: 0)
下载附件?保存到相册
相序继电器接线图
前天?11:04 上传
将被监测的三相电源接至L1,L2,L3端子上,同时可作为相序继电器的供电源,因而无需另外提供单独电源。
自带2路输出继电器可作为故障报警和电路通、断控制。
工作过程:当端子通电时,如果相序正确并且无缺相时,黄色LED灯亮,相序继电器的常开吸合,安全回路接触器吸合,然后控制电梯驱动系统得电。如检测到三相电源缺相或任意两项错相时,控制触点断开,接触器分断,使电梯不能启动或立即停止,及时有效的保护了人身及设备的安全。
范文五:保护继电器接线图
保护继电器接线图
继电器接线图目前国内生产的保护继电器,最常用的结构有三种 (系列 ) 本样本统称为通用结构。
(1)固定安装 10系列结构 (简称上继结构 ) 这种结构的继电器整体固定安装, 基本结构为突出式板后接线, 加 上附件后也可作板前接线使用。静态继电器样本中使用二种结构形式,如附图 1-2所示。
(2)凸出式插拔 20系列结构 (简称阿继结构 ) 这种结构的继电器可与底座插拔分离。基本结构为凸出式安装, 板后接线,静态继电器的样本中使用 JK-1、 JK-2、 JK-5三种结构形式,如附图 3-5所示。
(3)嵌入式插拔 30系列结构 (简称许继结构 ) 这种结构的继电器机芯可与壳体插拔分离。 静态继电器样本中使 用 A01K 、 A11K 二种,如附图 6-7所示
转载请注明出处范文大全网 » QSM11电器接线图