范文一:超限审查
超限高层建筑工程抗震设防专项审查技术要点
第一章 总则
第一条 为做好全国及各省、自治区、直辖市超限高层建筑工程抗震设防专家委员会的专项审查工作,根据《行政许可法》和《超限高层建筑工程抗震设防管理规定》(建设部令第111号),制定本技术要点。
第二条 下列工程属于超限高层建筑工程:
(一) 房屋高度超过规定,包括超过《建筑抗震设计规范》(以下简称《抗震规范》)第6章钢筋混凝土结构和第8章钢结构最大适用高度、超过《高层建筑混凝土结构技术规程》(以下简称《高层混凝土结构规程》)第7章中有较多短肢墙的剪力墙结构、第10章中错层结构和第11章混合结构最大适用高度的高层建筑工程。
(二) 房屋高度不超过规定,但建筑结构布置属于《抗震规范》、《高层混凝土结构规程》规定的特别不规则的高层建筑工程。
(三) 房屋高度大于24米且屋盖结构超出《网架结构设计与施工规程》和《网壳结构技术规程》规定的常用形式的大型公共建筑工程(暂不含轻型的膜结构)。
超限高层建筑工程的主要范围参见附录一。
第三条 在本技术要点第二条规定的超限高层建筑工程中,属于下列情况的,建议委托全国超限高层建筑工程抗震设防审查专家委员
— 1 —
会进行抗震设防专项审查:
(一) 高度超过《高层混凝土结构规程》B级高度的混凝土结构,高度超过《高层混凝土结构规程》第11章最大适用高度的混合结构;
(二) 高度超过规定的错层结构,塔体显著不同或跨度大于24m的连体结构,同时具有转换层、加强层、错层、连体四种类型中三种的复杂结构,高度超过《抗震规范》规定且转换层位置超过《高层混凝土结构规程》规定层数的混凝土结构,高度超过《抗震规范》规定且水平和竖向均特别不规则的建筑结构;
(三) 超过《抗震规范》第8章适用范围的钢结构;
(四) 各地认为审查难度较大的其他超限高层建筑工程。
第四条 对主体结构总高度超过350m的超限高层建筑工程的抗震设防专项审查,应满足以下要求:
(一) 从严把握抗震设防的各项技术性指标;
(二) 全国超限高层建筑工程抗震设防审查专家委员会进行的抗震设防专项审查,应会同工程所在地省级超限高层建筑工程抗震设防审查专家委员会共同开展,或在当地超限高层建筑工程抗震设防审查专家委员会工作的基础上开展;
(三) 审查后及时将审查信息录入全国重要超限高层建筑数据库,审查信息包括超限高层建筑工程抗震设防专项审查申报表项目(附录二)和超限高层建筑工程抗震设防专项审查情况表(附录三)。
第五条 建设单位申报抗震设防专项审查的申报材料应符合第二章的要求。专家组提出的专项审查意见应符合第六章的要求。
— 2 —
对于本技术要点第二条(三)款规定的建筑工程的抗震设防专项审查,除参照第三、四章的相关内容外,应按第五章执行。
第二章 申报材料的基本内容
第六条 建设单位申报抗震设防专项审查时,应提供以下资料:
(一) 超限高层建筑工程抗震设防专项审查申报表(申报表项目见附录二, 至少5份);
(二) 建筑结构工程超限设计的可行性论证报告(至少5份);
(三) 建设项目的岩土工程勘察报告;
(四) 结构工程初步设计计算书(主要结果,至少5份);
(五) 初步设计文件(建筑和结构工程部分,至少5份);
(六) 当参考使用国外有关抗震设计标准、工程实例和震害资料及计算机程序时,应提供理由和相应的说明;
(七) 进行模型抗震性能试验研究的结构工程,应提交抗震试验研究报告。
第七条 申报抗震设防专项审查时提供的资料,应符合下列具体要求:
(一) 高层建筑工程超限设计可行性论证报告应说明其超限的类型(如高度、转换层形式和位置、多塔、连体、错层、加强层、竖向不规则、平面不规则、超限大跨空间结构等)和程度,并提出有效控制安全的技术措施,包括抗震技术措施的适用性、可靠性,整体结构及其薄弱部位的加强措施和预期的性能目标。
(二) 岩土工程勘察报告应包括岩土特性参数、地基承载力、场地 — 3 —
类别、液化评价、剪切波速测试成果及地基方案。当设计有要求时,应按规范规定提供结构工程时程分析所需的资料。
处于抗震不利地段时,应有相应的边坡稳定评价、断裂影响和地形影响等抗震性能评价内容。
(三) 结构设计计算书应包括:软件名称和版本,力学模型,电算的原始参数(是否考虑扭转耦连、周期折减系数、地震作用修正系数、内力调整系数、输入地震时程记录的时间、台站名称和峰值加速度等),结构自振特性(周期,扭转周期比,对多塔、连体类含必要的振型)、位移、扭转位移比、结构总重力和地震剪力系数、楼层刚度比、墙体(或筒体)和框架承担的地震作用分配等整体计算结果,主要构件的轴压比、剪压比和应力比控制等。
对计算结果应进行分析。采用时程分析时,其结果应与振型分解反应谱法计算结果进行总剪力和层剪力沿高度分布等的比较。对多个软件的计算结果应加以比较,按规范的要求确认其合理、有效性。
(四) 初步设计文件的深度应符合《建筑工程设计文件编制深度的规定》的要求,设计说明要有建筑抗震设防分类、设防烈度、设计基本地震加速度、设计地震分组、结构的抗震等级等内容。
(五) 抗震试验数据和研究成果,要有明确的适用范围和结论。
第三章 专项审查的控制条件
第八条 抗震设防专项审查的重点是结构抗震安全性和预期的性能目标。为此,超限工程的抗震设计应符合下列最低要求:
(一) 严格执行规范、规程的强制性条文,并注意系统掌握、全面 — 4 —
理解其准确内涵和相关条文。
(二) 不应同时具有转换层、加强层、错层、连体和多塔等五种类型中的四种及以上的复杂类型。
(三) 房屋高度在《高层混凝土结构规程》B级高度范围内且比较规则的高层建筑应按《高层混凝土结构规程》执行。其余超限工程,应根据不规则项的多少、程度和薄弱部位,明确提出为达到安全而比现行规范、规程的规定更严格的针对性强的抗震措施或预期性能目标。其中,房屋高度超过《高层混凝土结构规程》的B级高度以及房屋高度、平面和竖向规则性等三方面均不满足规定时,应提供达到预期性能目标的充分依据,如试验研究成果、所采用的抗震新技术和新措施、以及不同结构体系的对比分析等的详细论证。
(四)在现有技术和经济条件下,当结构安全与建筑形体等方面出现矛盾时,应以安全为重;建筑方案(包括局部方案)设计应服从结构安全的需要。
第九条 对超高很多或结构体系特别复杂、结构类型特殊的工程,当没有可借鉴的设计依据时,应选择整体结构模型、结构构件、部件或节点模型进行必要的抗震性能试验研究。
第四章 专项审查的内容
第十条 专项审查的内容主要包括:
(一) 建筑抗震设防依据;
(二) 场地勘察成果;
(三) 地基和基础的设计方案;
— 5 —
(四) 建筑结构的抗震概念设计和性能目标;
(五) 总体计算和关键部位计算的工程判断;
(六) 薄弱部位的抗震措施;
(七) 可能存在的其他问题。
对于特殊体型或风洞试验结果与荷载规范规定相差较大的风荷载取值以及特殊超限高层建筑工程(规模大、高宽比大等)的隔震、减震技术,宜由相关专业的专家在抗震设防专项审查前进行专门论证。
第十一条 关于建筑结构抗震概念设计:
(一) 各种类型的结构应有其合适的使用高度、单位面积自重和墙体厚度。结构的总体刚度应适当(含两个主轴方向的刚度协调符合规范的要求),变形特征应合理;楼层最大层间位移和扭转位移比符合规范、规程的要求。
(二) 应明确多道防线的要求。框架与墙体、筒体共同抗侧力的各类结构中,框架部分地震剪力的调整应依据其超限程度比规范的规定适当增加。主要抗侧力构件中沿全高不开洞的单肢墙,应针对其延性不足采取相应措施。
(三) 超高时应从严掌握建筑结构规则性的要求,明确竖向不规则和水平向不规则的程度,应注意楼板局部开大洞导致较多数量的长短柱共用和细腰形平面可能造成的不利影响,避免过大的地震扭转效应。对不规则建筑的抗震设计要求,可依据抗震设防烈度和高度的不同有所区别。
主楼与裙房间设置防震缝时,缝宽应适当加大或采取其他措施。 — 6 —
(四) 应避免软弱层和薄弱层出现在同一楼层。
(五)转换层应严格控制上下刚度比;墙体通过次梁转换和柱顶墙体开洞,应有针对性的加强措施。水平加强层的设置数量、位置、结构形式,应认真分析比较;伸臂的构件内力计算宜采用弹性膜楼板假定,上下弦杆应贯通核心筒的墙体,墙体在伸臂斜腹杆的节点处应采取措施避免应力集中导致破坏。
(六) 多塔、连体、错层等复杂体型的结构,应尽量减少不规则的类型和不规则的程度;应注意分析局部区域或沿某个地震作用方向上可能存在的问题,分别采取相应加强措施。
(七) 当几部分结构的连接薄弱时,应考虑连接部位各构件的实际构造和连接的可靠程度,必要时可取结构整体模型和分开模型计算的不利情况,或要求某部分结构在设防烈度下保持弹性工作状态。
(八) 注意加强楼板的整体性,避免楼板的削弱部位在大震下受剪破坏;当楼板在板面或板厚内开洞较大时,宜进行截面受剪承载力验算。
(九) 出屋面结构和装饰构架自身较高或体型相对复杂时,应参与整体结构分析,材料不同时还需适当考虑阻尼比不同的影响,应特别加强其与主体结构的连接部位。
(十)高宽比较大时,应注意复核地震下地基基础的承载力和稳定。 第十二条 关于结构抗震性能目标:
(一) 根据结构超限情况、震后损失、修复难易程度和大震不倒等确定抗震性能目标。即在预期水准(如中震、大震或某些重现期的地震)
— 7 —
的地震作用下结构、部位或结构构件的承载力、变形、损坏程度及延性的要求。
(二) 选择预期水准的地震作用设计参数时,中震和大震可仍按规范的设计参数采用。
(三) 结构提高抗震承载力目标举例:水平转换构件在大震下受弯、受剪极限承载力复核。竖向构件和关键部位构件在中震下偏压、偏拉、受剪屈服承载力复核,同时受剪截面满足大震下的截面控制条件。竖向构件和关键部位构件中震下偏压、偏拉、受剪承载力设计值复核。
(四) 确定所需的延性构造等级。中震时出现小偏心受拉的混凝土构件应采用《高层混凝土结构规程》中规定的特一级构造,拉应力超过混凝土抗拉强度标准值时宜设置型钢。
(五) 按抗震性能目标论证抗震措施(如内力增大系数、配筋率、配箍率和含钢率)的合理可行性。
第十三条 关于结构计算分析模型和计算结果:
(一) 正确判断计算结果的合理性和可靠性,注意计算假定与实际受力的差异(包括刚性板、弹性膜、分块刚性板的区别),通过结构各部分受力分布的变化,以及最大层间位移的位置和分布特征,判断结构受力特征的不利情况。
(二) 结构总地震剪力以及各层的地震剪力与其以上各层总重力荷载代表值的比值,应符合抗震规范的要求,Ⅲ、Ⅳ类场地时尚宜适当增加(如10%左右)。当结构底部的总地震剪力偏小需调整时,其以上各层的剪力也均应适当调整。
— 8 —
(三) 结构时程分析的嵌固端应与反应谱分析一致,所用的水平、竖向地震时程曲线应符合规范要求,持续时间一般不小于结构基本周期的5倍(即结构屋面对应于基本周期的位移反应不少于5次往复);弹性时程分析的结果也应符合规范的要求,即采用三组时程时宜取包络值,采用七组时程时可取平均值。
(四) 软弱层地震剪力和不落地构件传给水平转换构件的地震内力的调整系数取值,应依据超限的具体情况大于规范的规定值;楼层刚度比值的控制值仍需符合规范的要求。
(五) 上部墙体开设边门洞等的水平转换构件,应根据具体情况加强;必要时,宜采用重力荷载下不考虑墙体共同工作的手算复核。
(六) 跨度大于24m的连体计算竖向地震作用时,宜参照竖向时程分析结果确定。
(七) 错层结构各分块楼盖的扭转位移比,应利用电算结果进行手算复核。
(八) 对于结构的弹塑性分析,高度超过200m应采用动力弹塑性分析;高度超过300m应做两个独立的动力弹塑性分析。计算应以构件的实际承载力为基础,着重于发现薄弱部位和提出相应加强措施。
(九) 必要时(如特别复杂的结构、高度超过200m的混合结构、大跨空间结构、静载下构件竖向压缩变形差异较大的结构等),应有重力荷载下的结构施工模拟分析,当施工方案与施工模拟计算分析不同时,应重新调整相应的计算。
(十) 当计算结果有明显疑问时,应另行专项复核。
第十四条 关于结构抗震加强措施:
— 9 —
(一) 对抗震等级、内力调整、轴压比、剪压比、钢材的材质选取等方面的加强,应根据烈度、超限程度和构件在结构中所处部位及其破坏影响的不同,区别对待、综合考虑。
(二) 根据结构的实际情况,采用增设芯柱、约束边缘构件、型钢混凝土或钢管混凝土构件,以及减震耗能部件等提高延性的措施。
(三) 抗震薄弱部位应在承载力和细部构造两方面有相应的综合措施。
第十五条 关于岩土工程勘察成果:
(一) 波速测试孔数量和布置应符合规范要求;测量数据的数量应符合规定。
(二) 液化判别孔和砂土、粉土层的标准贯入锤击数据以及粘粒含量分析的数量应符合要求;水位的确定应合理。
(三)场地类别划分、液化判别和液化等级评定应准确、可靠;脉动测试结果仅作为参考。
(四)处于不同场地类别的分界附近时,应要求用内插法确定计算地震作用的特征周期。
第十六条 关于地基和基础的设计方案:
(一) 地基基础类型合理,地基持力层选择可靠。
(二) 主楼和裙房设置沉降缝的利弊分析正确。
(三) 建筑物总沉降量和差异沉降量控制在允许的范围内。
第十七条 关于试验研究成果和工程实例、震害经验:
(一) 对按规定需进行抗震试验研究的项目,要明确试验模型与实 — 10 —
际结构工程相符的程度以及试验结果可利用的部分。
(二) 借鉴国外经验时,应区分抗震设计和非抗震设计,了解是否经过地震考验,并判断是否与该工程项目的具体条件相似。
(三) 对超高很多或结构体系特别复杂、结构类型特殊的工程,宜要求进行实际结构工程的动力特性测试。
第五章 超限大跨空间结构的审查
第十八条 关于可行性论证报告:
(一) 明确所采用的大跨屋盖的结构形式和具体的结构安全控制荷载和控制目标。
(二) 列出所采用的屋盖结构形式与常用结构形式在振型、内力分布、位移分布特征等方面的不同。
(三) 明确关键杆件和薄弱部位,提出有效控制屋盖构件承载力和稳定的具体措施,详细论证其技术可行性。
第十九条 关于结构计算分析: (一) 作用和作用效应组合:
设防烈度为7度(0.15g)及以上时,屋盖的竖向地震作用应参照时程分析结果按支承结构的高度确定。
基本风压和基本雪压应按100年一遇采用;屋盖体型复杂时,屋面积雪分布系数、风载体型系数和风振系数,应比规范要求增大或经风洞试验等方法确定;屋盖坡度较大时尚宜考虑积雪融化可能产生的滑落冲击荷载。尚可依据当地气象资料考虑可能超出荷载规范的风力。
温度作用应按合理的温差值确定。应分别考虑施工、合拢和使用
— 11 —
三个不同时期各自的不利温差。
除有关规范、规程规定的作用效应组合外,应增加考虑竖向地震为主的地震作用效应组合。
(二) 计算模型和设计参数
屋盖结构与支承结构的主要连接部位的构造应与计算模型相符。 计算模型应计入屋盖结构与下部结构的协同作用。
整体结构计算分析时,应考虑支承结构与屋盖结构不同阻尼比的影响。若各支承结构单元动力特性不同且彼此连接薄弱,应采用整体模型与分开单独模型进行静载、地震、风力和温度作用下各部位相互影响的计算分析的比较,合理取值。
应进行施工安装过程中的内力分析。地震作用及使用阶段的结构内力组合,应以施工全过程完成后的静载内力为初始状态。
除进行重力荷载下几何非线性稳定分析外,必要时应进行罕遇地震下考虑几何和材料非线性的弹塑性分析。
超长结构(如大于400m)应按《抗震规范》的要求考虑行波效应的多点和多方向地震输入的分析比较。
第二十条 关于屋盖构件的抗震措施: (一) 明确主要传力结构杆件,采取加强措施。
(二) 从严控制关键杆件应力比及稳定要求。在重力和中震组合下以及重力与风力组合下,关键杆件的应力比控制应比规范的规定适当加严
(三) 特殊连接构造及其支座在罕遇地震下安全可靠,并确保屋盖
— 12 —
的地震作用直接传递到下部支承结构。
(四) 对某些复杂结构形式,应考虑个别关键构件失效导致屋盖整体连续倒塌的可能。
第二十一条 关于屋盖的支承结构: (一) 支座(支承结构)差异沉降应严格控制。
(二) 支承结构应确保抗震安全,不应先于屋盖破坏;当其不规则性属于超限专项审查范围时,应符合本技术要点的有关要求。
(三) 支座采用隔震、滑移或减震等技术时,应有可行性论证。
第六章 专项审查意见
第二十二条 抗震设防专项审查意见主要包括下列三方面内容: (一) 总评。对抗震设防标准、建筑体型规则性、结构体系、场地评价、构造措施、计算结果等做简要评定。
(二) 问题。对影响结构抗震安全的问题,应进行讨论、研究,主要安全问题应写入书面审查意见中,并提出便于施工图设计文件审查机构审查的主要控制指标(含性能目标)。
(三) 结论。分为“通过”、“修改”、“复审”三种。
审查结论“通过”,指抗震设防标准正确,抗震措施和性能设计目标基本符合要求;对专项审查所列举的问题和修改意见,勘察设计单位应明确其落实方法。依法办理行政许可手续后,在施工图审查时由施工图审查机构检查落实情况。
审查结论“修改”,指抗震设防标准正确,建筑和结构的布置、计算和构造不尽合理、存在明显缺陷;对专项审查所列举的问题和修改
— 13 —
意见,勘察设计单位落实后所能达到的具体指标尚需经原专项审查专家组再次检查。因此,补充修改后提出的书面报告需经原专项审查专家组确认已达到“通过”的要求,依法办理行政许可手续后,方可进行施工图设计并由施工图审查机构检查落实。
审查结论“复审”,指存在明显的抗震安全问题、不符合抗震设防要求、建筑和结构的工程方案均需大调整。修改后提出修改内容的详细报告,由建设单位按申报程序重新申报审查。
第七章 附则
第二十三条 本技术要点由全国超限高层建筑工程抗震设防审查专家委员会办公室负责解释。
— 14 —
附录一:超限高层建筑工程主要范围的参照简表
表一 房屋高度(m)超过下列规定的高层建筑工程
结构类型
混凝土
结构
6度 60 130 140 120 150 180 80 200 220 110 220 300
混合结构
钢结构
框架-抗震墙 抗震墙 部分框支抗震墙 框架-核心筒 筒中筒 板柱-抗震墙 较多短肢墙
错层的抗震墙和框架-抗震
墙
钢外框-钢筋混凝土筒 型钢混凝土外框-钢筋混凝土
筒 框架
框架-支撑 (抗震墙板) 各类筒体和巨型结构
(含0.15g) 50 120 120 100 130 150 70 100 80 160 190 110 220 300
(0.20g) 40 100 100 80 100 120 55 60 60 120 150 90 200 260
(0.30g) 35 80 80 50 90 100 40 60 60 120 150 70 180 240
9度 24 50 60 不应采用
70 80 不应采用 不应采用 不应采用
70 70 50 140 180
注:当平面和竖向均不规则(部分框支结构指框支层以上的楼层不规则)时,其高度应比表内数值降
低至少10%;
表二、同时具有下列三项及以上不规则的高层建筑工程(不论高度是否大于表一)
序号
1a
不规则 类型
扭转不规则
简要涵义
考虑偶然偏心的扭转位移比大于1.2
邻层质应边长平面凹凸尺寸大于相应边长30%等
细叠备注
参见GB50011-3.4.2 参见参见GB50011-3.4.2 参见参见GB50011-3.4.2 参见GB50011-3.4.2 参见GB50011-3.4.2 参见GB50011-3.4.2
1b 2a 凹凸不规则 2b 组3 楼板不连续 4a
刚度突变
有效宽度小于50%,开洞面积大于30%,错层大于梁高 相邻层刚度变化大于70%或连续三层变化大于80% 上下墙、柱、支撑不连续,含加强层、连体类 相邻层受剪承载力变化大于80%
如局部的穿层柱、斜柱、夹层、个别构件错层或转换
4b 尺寸突变 5 构件间断 6 7
承载力突变 其它不规则
竖向构件位置缩进大于25%,或外挑大于10%和4m,多塔 参见JGJ3-4.4.5
已计入1~6项者除外
注:深凹进平面在凹口设置连梁,其两侧的变形不同时仍视为凹凸不规则,不按楼板不连续中的开洞对待;
序号a、b不重复计算不规则项;
局部的不规则,视其位置、数量等对整个结构影响的大小判断是否计入不规则的一项。
— 15 —
表三、具有下列某一项不规则的高层建筑工程(不论高度是否大于表一)
序号 不规则类型
1 2 3 4 5 6 7 8
扭转偏大
简要涵义
裙房以上的较多楼层,考虑偶然偏心的扭转位移比大于1.4
扭转周期比大于0.9, 混合结构扭转周期比大于0.85
抗扭刚度弱
层刚度偏小
本层侧向刚度小于相邻上层的50%
框支墙体的转换构件位置:7度超过5层,8度超过3层 7~9度设防的厚板转换结构
单塔或多塔与大底盘的质心偏心距大于底盘相应边长20%
高位转换 厚板转换 塔楼偏置
复杂连接
各部分层数、刚度、布置不同的错层
连体两端塔楼高度、体型或者沿大底盘某个主轴方向的振动周期显著不同的结构
结构同时具有转换层、加强层、错层、连体和多塔等复杂类型的3种
多重复杂
注:仅前后错层或左右错层属于表二中的一项不规则,多数楼层同时前后、左右错层属于本表的复杂连接;
表四、其他高层建筑
序号
1
简称 简要涵义
特殊类型 抗震规范、高层混凝土结构规程和高层钢结构规程暂未列入的其他高层建筑高层建筑 结构,特殊形式的大型公共建筑及超长悬挑结构,特大跨度的连体结构等 屋盖的跨度大于120m或悬挑长度大于40m或单向长度大于300m,屋盖结构
超限大跨 形式超出常用空间结构形式的大型列车客运候车室、一级汽车客运候车楼、空间结构 一级港口客运站、大型航站楼、大型体育场馆、大型影剧院、大型商场、大
型博物馆、大型展览馆、大型会展中心,以及特大型机库等
2
注:表中大型建筑工程的范围,参见《建筑工程抗震设防分类标准》GB 50223
说明:
1、当规范、规程修订后,最大适用高度等数据相应调整。
2、具体工程的界定遇到问题时,可从严考虑或向全国、工程所在地省级超限高层建筑工程抗震设防专项审查委员会咨询。
— 16 —
附录二:超限高层建筑工程抗震设防专项审查申报表项目
1.基本情况(包括:建设单位,工程名称,建设地点,建筑面积,申报日期,勘察单位及资质,设计单位及资质,联系人和方式等)
2.抗震设防标准(包括:设防烈度或设计地震动参数,抗震设防分类等)
3.勘察报告基本数据(包括:场地类别,等效剪切波速和覆盖层厚度,液化判别,持力层名称和埋深,地基承载力和基础方案,不利地段评价等)
4.基础设计概况(包括:主楼和裙房的基础类型,基础埋深,地下室底板和顶板的厚度,桩型和单桩承载力,承台的主要截面等)
5.建筑结构布置和选型(包括:主楼高度和层数,出屋面高度和层数,裙房高度和层数,特大型屋盖的尺寸;防震缝设置;建筑平面和竖向的规则性;结构类型是否属于复杂类型;特大型屋盖结构的形式;混凝土结构抗震等级等)
6.结构分析主要结果(包括:计算软件;总剪力和周期调整系数,结构总重力和地震剪力系数,竖向地震取值;纵横扭方向的基本周期;最大层位移角和位置、扭转位移比;框架柱、墙体最大轴压比;构件最大剪压比和钢结构应力比;楼层刚度比;框架部分承担的地震作用;时程法的波形和数量,时程法与反应谱法结果比较,隔震支座的位移;大型空间结构屋盖稳定性等)
7.超限设计的抗震构造(包括:结构构件的混凝土、钢筋、钢材的最高和最低材料强度;关键部位梁柱的最大和最小截面,关键墙体和筒体的最大和最小厚度;短柱和穿层柱的分布范围;错层、连体、转换梁、
— 17 —
转换桁架和加强层的主要构造;关键钢结构构件的截面形式、基本的连接构造;型钢混凝土构件的含钢率和构造等)
8.需要重点说明的问题(包括:性能设计目标简述;超限工程设计的主要加强措施,有待解决的问题,试验结果等)
注:填表人根据工程项目的具体情况增减,自行制表,以下为示例。
— 18 —
超限高层建筑工程初步设计抗震设防审查申报表 (示例)
编号: 申报时间:
申报人
工程名称
联系方式
建设单位 建筑面积 地上 万m 地下 万m 设计单位 设防烈度 度( g),设计 组 勘察单位 设防类别 类
建设地点
场地类别 液化判别 基础 持力层 结构类型 计算软件 计算参数
建筑高度和层数
类,波速 覆盖层 平面尺寸 液化等级 液化处理 和规则性 类型 埋深 桩长(或底板厚度) 竖向 名称 承载力 规则 性 抗震等级
周期折减 楼面刚度(刚□弹□分段□地震方向(单□双□斜□竖□) GE= 平均重力 X= Y=
X: Y: T:
X= (n= ) 对应扭转比 Y= (n= ) 对应扭转比
材料强度 (范围) 梁截面 柱截面
墙厚 钢 梁
主楼 m(n= )出屋面
地下 m(n= )相连裙房 m 长宽比
高宽比
框架 墙、筒
框支层 加强层 错层 梁 柱 墙 楼板 下部 剪压比 标准层
下部 轴压比 中部 轴压比 顶部 轴压比 下部 轴压比 中部 轴压比 顶部 轴压比 截面形式 长细比
地上总重 剪力系数 (%) 自振周期 (s) 最大层间 位移角
扭转位移比X= (n= ) 对应位移角 (偏心5%) Y= (n= ) 对应位移角
波形 时峰值 程剪力 分比较 析 位移 比较 弹塑性位 移角 框架承担 的比例 大型屋盖 超限设计 简要说明
位置范围 剪压比
位置范围 穿层数
1 2 3 位置n= 转换梁截面 X Y X= (底部),X = (顶部) 满布 局部(位置范围)
错层
Y= (底部),Y = (顶部) 错层高度 平层间距 X= (n= ) 连体 数量 支座高度 Y= (n= ) 含连廊 竖向地震系数 跨度 X= (n= ) 加强层 数量 位置 形式(梁□桁架□) Y= (n= ) 刚度比 X Y 倾覆力矩X= Y= 多塔 数量 形式(等高□对称□大小不等□) 总剪力 X= Y= 上下偏心 X Y
结构形式 尺寸 支座高度 支座连接方式 最大位移 竖向振动周期 竖向地震系数 构件应力比范围
(性能设计目标简述;超限工程设计的主要加强措施,有待解决的问题等等)
柱 支撑 短柱 穿层柱 转换层 刚度比
— 19 —
附录三
超限高层建筑工程专项审查情况表
工程名称
审查 主持单位 审查时间
姓名
职称
审查地点
单位
审查专家组 组长
副组长
审查组成员 (按实际人数
增减)
专家组 审查意见
审查结论 通过□ 修改□ 复审□
主管部门给建设单位的复函
(扫描件)
— 20 —
范文二:超限审查技术要点中关于大跨空间结构的补充内容介绍
第七届中日建筑结构技术交流会重庆
超限审查技术要点中关于大跨空间结构的补充内容介绍
甘明
北京市建筑设计研究院
Abstract
Inthepresentpaper,thelongspanstructureseismiccheckingrequirementisintroduced.Someexplainingisdiscussedinthispaper.
依据建设部抗震办公室的要求,由高层超限专家审查委员会和中国建筑科学研究院主持,制定了超限审查技术要点中关于大跨空间结构的补充内容,本文是笔者对有关内容的理解。
1需要审查的大跨空间结构屋盖’
檐口高度大于28米且跨度大于120m、悬挑长度大于40m或单向长度大于300m且屋盖结构形式为非常用空间结构形式的大型列车客运候车室、一级汽车客运候车楼、一级港口客运站、大型候机楼、大型体育场馆、大型影剧院、大型商场、大型博物馆、大型展览馆、大型会展中心。
之所以作上述规定是基于以下考虑:.
(1)我国目前只有高层抗震审查的行政许可,因此只能审查檐口高度为28’米以上的大跨空间结构。网架规程规定跨度使用为120米以内,所以我们把跨度120米定为审查界限。
大跨空间结构设计中风荷载往往是控制荷载,悬臂结构长度超过40米后,风振作用增大,和地震荷载组合后往往起控制作用。
风荷载是建筑结构的一个重要荷载,对大悬臂空间结构来说,风荷载是一个特别重要的荷载,这是因为此类空间结构的屋面大部分采用轻型屋面,故空间结构的静荷载一般都比较小。同时,由于此类结构的自重较轻,使得作用在空间结构上的地震荷载也较小。而和自重关系不大的风荷载在许多工程中都起控制作用,是结构工程师需要倍加关注的设计参数。
风荷载的计算需要四个参数,即
Wk=p牡秘∥o
这里W。是风荷载的标准值,尼是风振系数,儿是结构的体型系数,可以通过风洞试验获得。心是结构的高度系数,W。是结构的基本风压,均可从荷载规范中获得。
目前我国结构荷载规范规定的风振系数是从对高层和高耸结构的研究中获得的,某些结论仅适用与高层和高耸结构,有些和空间结构的风振作用甚至是矛盾的。例如:荷载规范规定结构高宽比小于1.5或结构高度小于30米都可以不考虑风振作用的影响。实际上空间结构高宽比越大越应该考虑风振作用。而影响空间结构的风振作用主要设计参数是416
空间结构的跨度。
空间结构和高层建筑的主要区别:,
a.高层建筑为典型悬臂式结构,基频振型为同向,以后各振型则有正负相间出现,可相互抵消一部分,因而第一振型起着主要作用。而空间网格结构,特别是体育场挑蓬,基频振型常为反对称形式,故其第二振型以后诸振型作用不可忽视。
b.高层建筑各振动频谱较为稀疏,而空间结构的振动频谱颇为密集,故其基频以后个频谱作用不能忽视。
同时由于空间结构的风振问题是一个随机振动问题,一般的大型线性有限元分析程序没有分析空间结构随机振动问题的功能,因而使一般设计人员没有解决此类问题的分析手段。
另外,由于屋面覆盖物厂家对结构的风振作用估计不足,在进行屋面覆盖物设计时往往忽略了风振作用,致使在强风作用下,屋面覆盖物被刮走或破损。因而,在考虑覆盖的连接强度时,就必须考虑空间网格的风振作用。北京西客站和西三旗加油站屋顶覆盖物就因未考虑空间网格结构的风振效应,覆盖物厂家又未和设计单位商量,自行进行连接设计,使覆盖物在强风作用下刮走。
同时,由于没有准确的估计风振作用j在设计空间结构,特别是悬臂结构时,往往使用一个很大的风振系数给包住。说这个风振系数取值大,既包括此数值本身就很大,另外也包括在正负风压是往往取相同的值.,而实际上正风压的体形系数往往小于负风压的体形系数,在实际设计时,正风压和自重及雪的荷载工况往往是空间网格结构的控制作用,这样有可能造成风荷载取值偏大,而且在各点的风振系数一般按最大值选取,这样就造成了结构的用钢量和其它经济指标的浪费,有时这种浪费的数量是较大的。
综上所述,我们认为对空间网格结构的风振的研究,特别对悬挑网壳结构和大悬臂网格结构的研究对今后空间网格结构的设计具有重要的现实意义。
(2)由于空间结构的造型往往比较复杂,一个大型空间结构的节点往往有上千个,甚至几千个。‘这样如果不依靠电子计算机的帮助,即使是计算最简单的高度系数也是不可能的。故有许多设计人员由于没有电子计算机的帮助,往往在设计中按空间结构的最高处选取高度系数,并估计一个较大的风振系数和体型系数,同时将荷载全部施加在空间结构的z方向。这样做往往造成结构的内力很大,使得结构的用钢量增加很多。由于有些时候结构的内力增加过多,甚至否定了建筑方案。为了进一步提高设计时风荷载的准确性,本文将电子计算机技术和风工程理论相结合,编制了计算空间网壳结构的风振系数、高度系数的程序。
(3)超长大跨空间结构由于地震的行波效应,(即地震波到达结构各点的时间滞后效应)会使结构产生附加的扭转作用。
国际上对于空间变异地震动的研究开始于1965年,Bogdanoff等人注意到地震动传播过程中的时滞效应对大跨度结构的影响。进入八、九十年代以后,随着计算机技术的发展和人们对地震动认识的深入,多维多点激励问题成为学者们的研究热点之一。由于桥梁的跨度要比建筑结构大得多,因此多点激励地震反应分析在桥梁领域的研究应用较建筑领域更为广泛。417
现有研究成果表明,对于超长型结构有必要进行多点输入地震反应分析。欧洲桥梁规范在规定地震作用时考虑了空间变化的地震运动特征,并指出在下面两种情况下应考虑地震运动的空间变化:①桥长大于200m,并且有地质上的不连续或明显的不同地貌特征;②桥长大于600m。
空间结构由于在次长方向的尺度远大于桥梁,因此由于地震波的行波效应引起的结构扭转效应比同等长度的桥梁结构要大,因此要点规定对单边长度大于300m的超长型结构,应当进行审查,对单边长度大于400m的超长型结构,应进行多点输入地震反应分析。2多维地震输入
以往的震害经验表明,地震时地面运动是多维的,在抗震设计中必须考虑地震动的多维性,在多维地震动作用下的结构反应是平一扭耦联的空间振动,当结构体型较大时应考虑多维地震输入o
3结构计算分析应着重符合下列要求
设防烈度为7度(0.159)及以上时,屋盖的竖向地震应参照竖向时程分析按支座高度3.1作用和作用效应组合比抗震规范对大跨度结构的要求相应放大。屋盖体型复杂时,屋面积雪分布系数、风载体型系数和风振系数,应比规范要求增大或经试验等方法确定。
除有关规范、规程规定的作用效应组合外,应增加考虑竖向地震为主的地震作用效应组合,以及风力为主的地震作用效应组合;可不考虑温度作用与地震作用效应组合。
之所以作上述规定是基于以下考虑-
(1)结构计算时,如果未和下部结构进行整体计算,应依据下部结构的具体情况考虑下部结构在地震作用下的放大作用。
(2)目前空间结构的风荷载计算比较粗糙,体形系数和风振系数往往靠估计,在进行复杂体形的大跨空间结构计算时,应当依据风洞试验,CFD分析获得结构的体形系数,依据随机振动理论获得结构的风振系数。
(3)目前抗震规范给出的地震组合主要适用于多高层结构,其横向作用为水平荷载,所以规范给出的组合以水平方向为主,由于大跨度结构的横向作用为竖向作用(如网架),或水平作用和竖向作用的组合(如网壳结构),因此,有必要考虑结构的竖向地震为主的地震作用效应组合。
(4)鉴于地震作用期间,常伴随大风、海啸等自然情况。有必要在进行抗震分析时考虑风荷载组合。
(5)我们认为下列荷载组合应在大跨度结构地震作用计算中考虑:
a.(1.2静载+0.6雪载)+1.3‘竖向地震+0.5水平地震
b.(1.2静载+0.6雪载)+1.3竖向地震+O.5水平地震+0.28风载
b.(1.2静载+O.6雪载)t1。.3竖向地震+0j5水平地震+o.28风载一0.2温度
d.(1.2静载+O.6雪载)+1.3竖向地震+O.5水平地震+0.2温度
7度:(1.2静载+0.6雪载):{:l:05
8度:(1-2静载+0.6雪载):l:1.1
9度:(1.2静载+0.6雪载):}:1.2(此时不考虑地震调整系数)418
e.在雪荷载较大的地区应当适当放大雪荷载值,体形复杂的网壳结构应当注意积雪效应对荷载不均匀性敏感的结构(如单层网壳)应当校核雪荷载不均匀分布。
£再使用反应谱方法计算地震作用的内力时,应当按下列方法考虑双向水平地震作用下产生的地震内力和结构的竖向地震作用下产生的地震内力的组合,即:
此时,结构竖向反应谱的数值为水平地震波的0.65倍属了丽孵镬■研蛹
g.在进行弹塑性时程分析时,X、Y、z向地震波的比例应为1:0.85:0.65和0.85:1:0.65
3.2计算模型和设计参数
空间结构构件与支承结构的主要连接部位的构造应与计算模型相符,提高计算结果的准确度。
应提供支承结构与空间结构不同阻尼比的整体结构计算分析比较。当各结构单元动力特性不同时,必要时应有整体计算与分开单独计算的‘比较。
必要时应通过考虑几何和材料非线性的弹塑性分析予以判断。
长度超过400米的超长结构应有多点多方向地震输入的分析比较。
必要时应有考虑屋盖施工过程模拟的不利情况的计算分析。
之所以作上述规定是基于以下考虑:
(1)目前许多空间结构的支座节点设计不能满足抗震计算时结构的计算支承条件,所得反力不符合结构的实际情况,在地震作用下会出现危险。目前有些施工单位为了施工方便,在支座下使用过渡板连接,而过渡板上面使用螺栓进行塞焊,这样,空间结构上面的水平力就通过节点传递给螺栓,这使螺栓有可能在承受弯、剪组合的内力时破坏,致使整个支座丧失承载能力,从所周知,支座是整个空间结构的生命线,支座破坏造成整个空间结构破坏的工程实例屡有发生。因此,大型空间结构在震区设计支座时应当进行认真核算,必要时应进行有限元实体分析或节点试验。
(2)空间结构在地震作用下的动力反应和下部结构密切相关,在相当多的情况下,有必要进行整体计算。但目前许多计算程序不能提供不同阻尼比同时进行计算的功能,可以在进行结构整体分析时,在计算下部结构为混凝土屋盖结构为钢结构的组合结构时,分别按整个结构阻尼取0.05(混凝土结构)和整个结构0.02(钢结构)进行计算。
(3)在八度、九度抗震设防区抗震等级为甲、乙类的大跨空间结构按抗震规范要求,应进行考虑几何非线性的弹塑性时程分析。
(4)对于结构长度超过400米的大跨空间结构,由于地震的行波效应,(即地震波到达结构各点的时间滞后效应)会使结构产生附加的扭转作用。因此,需要进行多点多方向地震输入的分析。
(5)对结构自重较大的大跨空间结构,由于施工过程是一个变结构、变约束的可变结构体系,因此有必要依据结构的施工过程进行施工过程模拟。
屋盖构件的抗震措施应着重符合下列要求:
(1)主次结构杆件应明确区分。
(2)关键杆件在罕遇地震下满足应力比、稳定控制。419
(3)特殊连接构造及其支座在罕遇地震下安全可靠o
(4)个别关键构件失效时,应防止屋盖连锁倒塌。
之所以作上述规定是基于以下考虑:
(1)从结构抗震性能化设计的要求,对于一些关键性杆件,应当在中震时保持弹性。(2)大跨空间结构的支座是结构传递荷载的关键部位,是大跨结构的生命线,有必要认真考虑结构支座节点的动力效应,必要时进行支座节点的有限元分析。
(3)结构的连续倒塌是需要认真防范的,对某些特别大跨空间结构,如果审查委员会认为必要,应作结构防止连续倒塌验算。
屋盖的支承结构应符合下列专门要求:
(1)支座(支承结构)总体沉降和差异沉降应严格控制。
(2)支承结构应确保罕遇地震安全,其不规则性属于超限专项审查范围时,应符合本技术要点的有关要求。
(3)支座采用隔震或滑移减震等技术时,应有可行性论证。
之所以作上述规定是基于以下考虑:
(1)支座的不均匀沉降会使大跨结构产生很大的附加内力,必须采取可靠措施加以防止。
(2)支座采用隔震或滑移减震等技术时,应进行多方案比对,应按阻尼的实际情况进行时程分析。
范文三:超限审查需准备的附件
超限审查需准备的附件:
1. 申请书;
2. 申请人身份证明材料;
3. 营业执照复印件;
4. 法人证明文件,法人授权委托书;
5. 建设用地规划设计条件;
6. 建设用地方案图;
7. 建筑方案设计批复;
8. 超限高层建筑工程抗震设防专项审查申报表(提交1份,备份5份);---(设计单位准备)
9. 设计单位设计资质证书;---(设计单位准备)
10. 初步设计(建筑和结构工程部分,提交1份,备份5份);---(设计单位准备)
11. 建设项目的岩土工程勘察报告;
12. 结构工程初步设计计算书(提交1份,备份5份);---(设计单位准备)
13. 建筑结构工程超限设计可行性论证报告(提交1份,备份5份);---(设计单位准备)
14. 进行模型抗震性能试验研究的结构工程,应提交抗震试验研究报告;---(设计单位准备)
15. 当参考使用国外有关抗震设计标准、工程实例和震害资料及计算机程序时,应提供理由和相应的说明。---(设计单位准备)
范文四:超限报告的主要内容
超限报告的主要内容
(虽说报告编制和样式具有多样性,但主要内容大多数是相似的,根据项目的特点重点分析内容会有差异)
目 录
1 工程概况···············································································································X
1.1 总体概况··························································································X
1.2 分区及分缝····················································································· X 2 设计依据··························································································X
2.1 设计规范及标准···············································································X
2.2 相关文件··························································································X
2.3 耐火等级··························································································X 3 材料···································································································X
3.1 混凝土······························································································X
3.2 主要构件混凝土强度等级··································································X
3.3 钢筋··································································································X
3.4 混凝土保护层····················································································X
3.5 钢材··································································································X
3.6 主要钢材等级····················································································X 4 荷载取值及验算要求······································································X
4.1 楼面活荷载·······················································································X
4.2 各层楼盖的活荷载折减系数······························································X
4.3 风荷载······························································································X
4.5 温度作用·····························································································X
4.6 作用效应组合······················································································X
4.7 中震弹性·····························································································X
4.8 大震不屈服、不屈曲···········································································X
4.9 验算要求·····························································································X
4.10 结构竖向变形限值·············································································X
4.11 结构水平变形限值·············································································X
4.12 结构舒适度控制·················································································X 5风洞试验结果及设计··········································································X
5.1 风洞试验的目的和原理及方法·····························································X
5.2风洞试验结果分析···············································································X
5.3规范风荷载取值与风洞试验结果的比较················································X
5.4结论及建议··························································································X 6 工程地质条件·····················································································X
6.1 概述····································································································X
6.2 地形地貌·····························································································X
6.3 地质构造·····························································································X
6.4 水文地质条件······················································································X
6.5 岩土层分布·························································································X
6.6 主要岩土层的力学指标········································································X
6.7 不良工程地质作用···············································································X
7 基础······································································································X
7.1 持力层选择··························································································X
7.2塔楼基础·······························································································X
7.3塔楼核心筒底板偏心距计算··································································X
7.4 裙房及地下室基础················································································X
7.5 地下室外墙及底板················································································X
7.6 沉降及差异沉降计算············································································X 8 基坑开挖与边坡稳定·········································································X
8.1 东侧基坑边坡······················································································X
8.2 西侧基坑边坡······················································································X
8.3 南侧基坑边坡······················································································X
8.4北侧基坑边坡······················································································X 9塔楼结构体系······················································································X
9.1 结构体系概述······················································································X
9.2 楼面布置·····························································································X
9.3 核心筒································································································X
9.4 外框柱································································································X
9.5 加强层环向腰桁架和伸臂桁架·····························································X 10塔楼抗震超限情况及性能设计目标···············································X 10.1 结构基本情况概述·············································································X 10.2 建筑结构抗震设防类别及抗震措施·····················································X
10.4 抗震性能设计目标···········································································X 11塔楼弹性分析(小震和中震)····················································X 11.1 计算软件························································································X 11.2 结构计算参数·················································································X 11.3 计算模型·······················································································X 11.4伸臂桁架敏感性分析·······································································X 11.5 弹性分析计算结果(周期、位移、重量、刚度、剪力、稳定等)····X 11.6结论与建议····················································································X 12 弹性时程分析··············································································X 12.1 分析软件·······················································································X 12.2分析原理和计算假定······································································X 12.3 时程分析与反应谱分析底部剪力对比············································X 12.4 时程分析计算结果分析·································································X 12.5结论与建议····················································································X 13 静力弹塑性推覆(Pushover )分析·······································X 13.1 分析软件······················································································X 13.2 分析模型和计算假定·····································································X 13.3 加载顺序与水平作用力的竖向分布···············································X 13.4 计算结果分析···············································································X 13.5结论与建议···················································································X 14动力弹塑性分析···········································································X
14.2分析原理和计算假定·······································································X 14.3 计算结果分析·················································································X 14.4结论与建议·····················································································X 15 构件检算(小震和中震及大震)··············································X 15.1 验算要求(偏压、偏拉、受剪、受弯)·········································X 15.2 荷载及内力组合············································································X 15.3 构件设计内力调整········································································X 15.4 框架柱的验算···············································································X 15.5 核心筒墙验算···············································································X 15.6 剪力墙连梁验算···········································································X 15.7 框架梁和楼面次梁验算································································X 15.8 腰桁架和伸臂桁架验算································································X 15.9 加强层区楼板分析与设计·····························································X 16楼板分析······················································································X 16.1 分析软件·····················································································X 16.2分析原理和计算假定····································································X 16.3 楼板应力分析··············································································X 16.4楼板振动舒适度分析····································································X 16.5结论与建议··················································································X 17施工模拟分析··············································································X 17.1分析软件······················································································X
17.3 施工阶段划分···············································································X 17.4 混凝土收缩和徐变分析·································································X 17.5 计算结果分析···············································································X 17.6结论与建议····················································································X 18 节点分析······················································································X 18.1 分析软件······················································································X 18.2分析原理和计算假定·····································································X 18.3计算结果分析················································································X 18.4结论与建议···················································································X 19整体和局部稳定屈曲分析·························································X 19.1 分析软件·····················································································X 19.2分析原理和计算假定····································································X 19.3 计算结果分析··············································································X 19.4结论与建议··················································································X 20加强层伸臂桁架分析·································································X 20.1 分析软件·····················································································X 20.2分析原理和计算假定·····································································X 20.3 计算结果分析··············································································X 20.4结论与建议···················································································X 21跃层柱屈曲分析··········································································X 21.1 分析软件······················································································X
21.3 计算结果分析··············································································X 21.4结论与建议···················································································X 22转换梁应力分析··········································································X 22.1 分析软件·····················································································X 22.2分析原理和计算假定·····································································X 22.3 计算结果分析··············································································X 22.4结论与建议···················································································X 23抗连续倒塌分析··········································································X 23.1 分析软件·····················································································X 23.2 分析原理和计算假定····································································X 23.3失效构件的选取············································································X 23.4荷载组合·······················································································X 23.5材料参数取值················································································X 23.6计算结果分析················································································X 23.7结论与建议····················································································X 24 针对性抗震措施···········································································X 25 总结论···························································································X 附件1: 超限高层建筑工程抗震设防专项审查申报表······························X 附件2: 模型主要输入输出资料······························································X 附件3 结构初步设计图纸······································································X 附件4 建筑初步设计图纸······································································X
范文五:超限审查管理办法
北京市建设委员会关于印发《北京市拟建重要建筑项目超限高层建筑工程抗震设防审查
及“三新核准”审核管理办法》的通知
(京建法[2007]102号)
各区、县建委,各集团、总公司,各有关单位:
为加强北京市拟建重要建筑项目的管理,保证重要建筑项目建设质量与安全,根据建设部《关于加强北京市拟建重要建筑项目监督管理的意见》(建法[2006]149号)及相关规定,特研究制定了《北京市拟建重要建筑项目超限高层建筑工程抗震设防审查及“三新核准”审核管理办法》,现印发给你们,请遵照执行。
北京市建设委员会
二00七年一月二十六日
北京市拟建重要建筑项目超限高层建筑工程
抗震设防审查及“三新核准”审核管理办法
第一章 总则
第一条 为加强北京市拟建重要建筑项目的管理,保证重要建筑项目建设质量与安全,按照建设部《关于加强北京市拟建重要建筑项目监督管理的意见》(建法[2006]149号)、《超限高层建筑工程抗震设防管理规定》(建设部令第111号)、《“采用不符合工程建设强制性标准的新技术、新工艺、新材料核准”行政许可实施细则》(建标[2005]124号),结合本市实际,制定本办法。
第二条 本办法适用于北京市重要建设项目超限高层建筑工程抗震设防审查以及“采用不符合工程建设强制性标准的新技术、新工艺、新材料核准”(以下简称“三新核准”)审核的管理。
本办法所称的超限高层建筑工程,是指超出国家现行规范、规程所规定的适用高度和适用结构类型的高层建筑工程,体型特别不规则的高层建筑工程,以及有关规范、规程规定应当进行抗震专项审查的高层建筑工程。
第三条 北京市建设委员会(以下简称市建委)依据职责负责本市超限高层建筑工程抗震设防审查及“三新核准”审核的工作。
第二章 超限高层建筑工程抗震设防审查
第四条 拟建重要建筑项目属于超限高层建筑工程的,其抗震设防应当满足《超限高层建筑工程抗震设防管理规定》(建设部令第111号)的相关要求,建设单位应当在项目初步设计阶段向市建委提出专项报告。
第五条 超限高层建筑工程的抗震设防专项审查内容包括:建筑的抗震设防分类、抗震设防烈度(或者设计地震动参数)、场地抗震性能评价、抗震概念设计、主要结构布置、建筑与结构的协调、使用的计算程序、结构计算结果、地基基础和上部结构抗震性能评估等。
1
第六条 建设单位申报超限高层建筑工程的抗震设防专项审查时,应当提供以下材料:
(1)建设单位申请超限高层建筑工程抗震设防审查专项报告;
(2)超限高层建筑工程抗震设防专项审查申报表(附件1);
(3)设计的主要内容、技术依据、可行性论证及主要抗震措施,结构抗震薄弱部位的分析和相应措施;
(4)工程勘察报告;
(5)结构设计计算的主要结果;
(6)初步设计文件(参考《建筑工程设计文件编制深度规定》制定);
(7)设计时参照使用的国外有关抗震设计标准、工程和震害资料及计算机程序;
(8)对要求进行模型抗震性能试验研究的,应当提供抗震试验研究报告;
(9)勘察、设计单位甲级资质证书。
同时提供第(2)、(3)、(5)、(6)项材料的电子文档。
第七条 超限高层建筑工程抗震设防专项审查费用由建设单位承担。
第八条 市建委自接到抗震设防专项审查全部申报材料之日起25个工作日内,负责组织专家委员会提出书面专项审查意见,并将审查结果通知建设单位。
第九条 市建委负责将抗震设防专项审查意见等有关材料报建设部备案。
第三章 “三新核准”审核
第十条 拟建重要建筑项目拟采用的新技术、新工艺、新材料不符合现行相关的工程建设强制性标准,或直接涉及到建设工程质量安全、公共安全以及人身健康、生命财产安全,且工程建设强制性标准没有规定又没有现行工程建设国家标准、行业标准和地方标准可依的,建设单位应当联合施工单位制定“三新”应用的施工技术方案,施工单位应当组织编写适用的企业标准(项目专项标准)。
第十一条 施工技术方案应包括编制依据、分部(项)工程概况、施工安排、施工准备、施工方法、质量标准、试验检测和验收等内容及施工、安全防护、消防、临时用电、环保等注意事项。企业标准应包含施工工艺与验收两项内容,标准结构和编写规则应符合《工程建设标准编写规定》的相关要求。
第十二条 施工技术方案及企业标准应经过专题技术论证会论证。
专题技术论证会应由施工单位配合建设单位提出审查申请,并将专家组成及组织方案报市建委同意后召开。
第十三条 专题技术论证会应有建设、设计、施工、监理等有关单位共同参加,评审专家不得少于7人,专家组成员应具备高级技术职称并在相关领域有丰富的工作经验。
第十四条 专题技术论证会应形成会议纪要,会议纪要应当包括会议概况、不符合工程建设强制性标准的情况说明、可行性概要分析、结论及专家组成员签字。
第十五条 市建委负责审核建设单位、施工单位提交的专题技术论证会议纪要和其他有关材料,出具对本项目的审核意见,并按照《北京市建设工程地方技术标准管理规定》对符合备案要求的企业标准进行备案。
2
第十六条 建设单位按照建设部建标[2005]124号文件的规定,向建设部标准定额司提出“三新核准”申请。待建设部核准后,施工方案方可实施。
第四章 附则
第十七条 本办法自2007年3月1日起施行。
附件1:
超限高层建筑工程抗震设防专项审查申报表项目
1(基本情况(包括:建设单位,工程名称,建设地点,建筑面积,申报日期,勘察单位及资质,设计单位及资质,联系人和方式等)
2(抗震设防标准(包括:设防烈度或设计地震动参数,抗震设防分类等)
3(勘察报告基本数据(包括:场地类别,等效剪切波速和覆盖层厚度,液化判别,持力层名称和埋深,地基承载力和基础方案,不利地段评价等)
4(基础设计概况(包括:主楼和裙房的基础类型,基础埋深,地下室底板和顶板的厚度,桩型和单桩承载力,承台的主要截面等)
5(建筑结构布置和选型(包括:主楼高度和层数,出屋面高度和层数,裙房高度和层数;防霹缝设置;建筑平面和竖向的规则性;结构类型是否属于复杂、特殊类型;大型空间结构屋盖的尺寸和结构形式;混凝土结构抗震等级等)
6(结构分析主要结果(包括:计算软件;总剪力和周期调整系数,结构总重力和地震剪力系数,竖向地震取值;纵横扭方向的基本周期;最大层位移角和位置、扭转位移比;框架柱、墙体最大轴压比;构件最大剪压比和钢构件应力比;楼层刚度比;框架部分承担的地震作用;时程法的波形和数量,时程法与反应谱法结果比较,隔震支座的位移;大型空间结构屋盖稳定性等)
7(超限设计的抗震构造(包括:结构构件的混凝土、钢筋、钢材的最高和最低材料强度;关键部位梁柱的最大和最小截面,关键墙体和简体的最大和最小厚度;短柱分布范围;错层、连体、转换梁、转换桁架和加强层的主要构造;关键钢结构构件的截面形式、基本的连接构造;型钢混凝土柱的含钢率和构造等)
8(需要重点说明的问题(包括:性能设计目标简述;超限工程设计的主要加强措施,有待解决的问题,试验结果等)
注:填表人根据工程项目的具体情况增减,自行制表,以下为示例。
超限高层建筑工程初步设计抗震设防专项审查申报表(示例)
编号: 申报时间:
????????????????????????????????????????????????? ? ? 申报人 ?
??工程名称 ? ? ?
3
?? ? ?联系方式 ?
??????????????????????????????????????????????????建设单位 ? ?建筑面积 ?地上
万?地下 万? ??????????????????????????????????????????????????设计单位 ? ?设防烈度 ?
度( g),设计 组 ??????????????????????????????????????????????????勘察单位 ? ?设防类别 ? 类 ?????????????????????????????????????????????????? ? ?建筑高度,?主楼 m(n, )出屋面 ??建设地点 ?
? ? ?? ?
?层 数 ?地下 m(n, )相连裙房 m ??????????????????????????????????????????????????场地类别 ? 类,波速
覆盖层 ? 平 面 ? 长宽比 ??液化判别 ? 液化等级 液化处理 ? 规则性 ? ?????????????????????????????????????????????????? 基础 ?类型 埋深 桩长(或底板厚度) ? 竖 向 ? 高宽比 ?? 持力层 ?名称 承载力 ? 规则性 ? ??????????????????????????????????????????????????
? ? ?框架 墙、筒 ??结构类型 ? ?抗震等级 ? ?? ? ? ?框支层 加强层 错层
?????????????????????????????????????????????????? ? ?材料强度 ?梁 柱
??计算软件 ? ? ?
?? ? ? (范围) ?墙
楼板 ?????????????????????????????????????????????????? ?周期折减 楼面刚度(刚弹 分段)? ?下部 剪压比 ??计算参数 ? ? 梁截面 ? ?? ?地震方向(单 双 斜 竖 ) ?
?标准层 ??????????????????????????????????????????????????地上总重 ?C(E下标), 平均重力 ? ?下部 轴压比 ??剪力系数 ?X,
? 柱截面 ?中部 ?? ?Y,
? ?顶部 ?? (,) ?
? ? ??????????????????????????????????????????????????自振周期 ?X:
? ?下部 轴压比 ?? (s) ?Y:
? 墙厚 ?中部 ?? ?T:
? ?顶部 ??????????????????????????????????????????????????最大层间
?X, (n, )扭转比 ?钢 梁 ?截面形式 长细比 ?? 位移角 ?Y, (n, )扭转比 ?柱 支撑 ? ????????????????????????????????????????????????
4
??扭转位移比 ?X, (n, )位移角 ? 短柱 ?位置范围 剪压比
??(偏心5,) ?Y, (n, )位移角 ? 穿层柱 ?位置范围 穿层数
?????????????????????????????????????????????????
????????????????????????????????????????????????? ?波形?1 2 3 ? ?位置n, 梁截面
?? ? ? ?转换层 ?X Y
?? ?峰值? ?刚度比 ?
??时? ? ? ?
?? ???????????????????????????????????????????????程?剪力?X, (n,1),X, (n, ) ? 错层 ?满布
局部(位置范围) ??分?比较?Y, (n,1),Y, (n, ) ? ?错层高度 平层间距 ?? ???????????????????????????????????????????????析? ?X, (n, ) ? 连体
?数量 支座高度 ?? ?位移?Y, (n, ) ?
?竖向地震系数 跨度 ?? ?比较? ? 含连廊? ??????????????????????????????????????????????????弹塑性位?X, (n, )
? ?数量 形式(梁 桁架 ) ?? ?Y, (n, )
? 加强层?X Y ?? 移角 ?
? 刚度比? ??????????????????????????????????????????????????框架承担?倾覆力矩X,
Y, ? 多塔 ?数量 形式(等高 对称 大小不等) ?? ?
? ?X Y ?? 的比例?总剪力 X, Y, ?上下偏心? ??????????????????????????????????????????????????大跨空间?结构形式 尺寸 支座高度 支座连接方式 最大位移 ??
控制荷载 竖向振动周期 竖向地震系数 构件应力比 结 构?
??????????????????????????????????????????????????超限设计?(性能设计目标简述;超限工程设计的主要加强措施,有待解决的问题等等)
??简要说明?
?????????????????????????????????????????????????
发布部门:北京市其他机构 发布日期:2007年01月26日 实施日期:2007年03月01日 (地方法规)
5