范文一:鱼线的线号与线径对照表
线号;0.4#????? 线径:0.10 mm???? 拉力值:2.2 kg
线号;0.6#????? 线径:0.12 mm????? 拉力值:2.7 kg
线号;0.8#????? 线径:0.14 mm????? 拉力值:3.5 kg
线号:1.0#????? 线径:0.16 mm???? 拉力值:4.7 kg
线号:1.2#????? 线径:0.18 mm???? 拉力值:5.7 kg
线号:1.5#????? 线径:0.20 mm???? 拉力值:6.8 kg?钓鱼知识学习网站
线号:2.0#????? 线径:0.23 mm???? 拉力值:8.5 kg
线号:2.5#????? 线径:0.26 mm???? 拉力值:9.6 kg
线号:3.0#????? 线径:0.28 mm???? 拉力值:10.6 kg
线号:3.5#????? 线径:0.30 mm???? 拉力值:11.8 kg
线号:4.0#????? 线径:0.32 mm???? 拉力值:13.9 kg
线号:4.5#????? 线径:0.34 mm???? 拉力值:14.8 kgdiaoyula.com
线号:5.0#????? 线径:0.37 mm???? 拉力值:16.5 kg
线号:6.0#????? 线径:0.40 mm???? 拉力值:18.7 kg?钓鱼啦
线号:7.0#????? 线径:0.45 mm???? 拉力值:20.4 kg
线号:8.0#????? 线径:0.50 mm???? 拉力值:22.5 kg
范文二:钓鱼基本技术-鱼线拉力与线径对照表
[推荐]线径拉力对照表
为了方便广大钓友购买钓线时鉴别钓线质量,特列出进口钓线号数与线径和拉力的对照
表,希望对大家有用。
表1 进口钓线号数与线径和拉力的对照表 子线 主线
号数 线径(mm) 拉力(Kg) 号数 线径(mm) 拉力(Kg) 0.07, 0.049 0.40 0.4, 0.104 1.08 0.1, 0.053 0.45 0.5, 0.121 1.33 0.2, 0.076 0.55 0.6, 0.128 1.51 0.3, 0.090 0.79 0.8, 0.148 2.02 0.4, 0.104 1.09 1.0, 0.165 2.53 0.5, 0.121 1.33 1.2, 0.181 2.85 0.6, 0.128 1.56 1.5, 0.205 3.71 0.8, 0.148 2.08 2.0, 0.235 4.88 1.0, 0.165 2.58 2.5, 0.260 5.55 1.2, 0.181 3.03 3.0, 0.285 6.40 1.5, 0.205 3.75 4.0, 0.331 8.41 1.7, 0.222 4.02 5.0, 0.375 10.10 2.0, 0.235 4.90 6.0, 0.405 11.86
表2 国产钓线号数与线径和拉力的对照表
范文三:线径对照表
AWG 標準線徑規格對照表
AWG 標準線徑規格對照表
上一頁
業界線徑的粗細是以號數(xxAWG)來表示的,數目越小表示線徑愈粗,所能承載的電流就越大,反之則線徑越細,耐電流量越小。例如說:12號的耐電流量是20安培,最大承受功率是2200瓦,而18號線的耐電流量則是7安培,最大承受功率是770瓦。
為什麼AWG 號數越小直徑反而越大?如這麼解釋你就會明白,固定的截面積下能塞相同的AWG 線的數量,如11#AWG號數可塞11根而15#AWG號數可塞15根,自然的15#AWG的單位線徑就較小。
美規線徑值單一導體或群導體【各正值或負值】的線徑值(Gauge)是以圓或平方厘米(mm) 量測而得,平方厘米不常用在量測線徑值,由於牽涉到不正確,因一般大部份的導體形體,包含長方形及其他怪異形狀。因此我們拿全部的量測以圓平方厘米(c/m)為參考值
2
群導體計算的方法或公式:
加上單一導體的線徑值總和,並比較上表求得。如果值落入兩者之間,取比較少的值。
40股群導體線的線徑值為,如每一芯為24 Guage = 40 x 405 c/m = 16,200 c/m = 9 AWG(得出值落入12960c/m和16440c/m之間)
快速求得線徑值的方法:
兩條(AWG)相加時,該單一線徑值減3. ex. 2 x 18 AWG = (18-3=) 15 AWG 三條(AWG)相加時,該單一線徑值減5. ex. 3 x 24 AWG = (24-5=) 19 AWG 四條(AWG)相加時,該單一線徑值減6. ex. 4 x 10 AWG = (10-6=) 04 AWG
請記得“快速求得線徑值的方法” 一些案例也許邊際會不正確,只採用此方式為大原則
AWG 標準線徑規格對照表
范文四:AWG线径对照表
美国电线电缆标准AWG对照表
外径
AWG
公制mm
4/03/02/01/01234567891011121314151617181920212223242526
11.684010.40389.26598.25257.34826.54305.82685.18924.62034.11483.66523.26392.90582.58832.30382.05231.82881.62811.45031.29031.15061.02360.91190.81280.72390.64260.57400.51050.45470.4039
英制inch0.46000.40960.36480.32490.28930.25760.22940.20430.18190.16200.14430.12850.11440.10190.09070.08080.07200.06410.05710.05080.04530.04030.03590.03200.02850.02530.02260.02010.01790.0159
截面积(mm2)107.219385.011467.432153.488042.408633.624026.665221.149216.765713.298010.55098.36696.63155.26154.16843.30812.62682.08201.65211.30761.03980.82290.65300.51890.41160.32430.25880.20470.16240.1281
电阻值(Ω/km)0.160.200.260.320.410.510.650.821.031.301.632.062.603.284.145.216.568.2810.4413.1816.5820.9526.4033.2341.8953.1666.6284.22106.19134.59
272829303132333435363738394041424344454647484950515253545556
外径
AWG
公制mm英制inch0.36070.32000.28700.25400.22610.20320.18030.16000.14220.12700.11430.10160.08890.07870.07110.06350.05590.05080.04470.03990.03560.03150.02820.02510.02240.01980.01780.01570.01400.0124
0.01420.01260.01130.01000.00890.00800.00710.00630.00560.00500.00450.00400.00350.00310.00280.00250.00220.00200.00180.00160.00140.00120.00110.00100.00090.00080.00070.00060.00060.0005
截面积(mm2)0.10220.08040.06470.05070.04010.03240.02550.02010.01590.01270.01030.00810.00620.00490.00400.00320.00250.00200.00160.00120.00100.00080.00060.00050.00040.00030.00020.00020.00020.0001
电阻值(Ω/km)168.74214.32266.47340.26429.56531.65674.98857.281085.001361.021680.272126.602777.603540.644339.995444.097030.078506.3910984.513804.017360.022129.027615.934716.443938.055926.369439.988516.0112481.2141714.1
范文五:线径电流对照表
铝线和铜线线径电流对照表
一般铜线安全计算方法是:
2.5平方毫米铜电源线的安全载流量--28A 。 4平方毫米铜电源线的安全载流量--35A 。 6平方毫米铜电源线的安全载流量--48A 。 10平方毫米铜电源线的安全载流量--65A 。 16平方毫米铜电源线的安全载流量--91A 。 25平方毫米铜电源线的安全载流量--120A 。 如果是铝线,线径要取铜线的1.5-2倍。
如果铜线电流小于28A ,按每平方毫米10A 来取肯定安全。 如果铜线电流大于120A ,按每平方毫米5A 来取。
绝缘导线载流量估算如下:
铝芯绝缘导线载流量与截面的倍数关系
导线截面(mm 2 ) 1 1. 5 2. 5 4 6 10 16 25 35 50 70 95 120 载流是截面倍数 9 8 7 6 5 4 3. 5 3 2. 5
载流量(A) 9 14 23 32 48 60 90 100 123 150 210 238 300 估算口诀:
二点五下乘以九,往上减一顺号走。 三十五乘三点五,双双成组减点五。 条件有变加折算,高温九折铜升级。 穿管根数二三四,八七六折满载流。 说明:
本节口诀对各种绝缘线(橡皮和塑料绝缘线) 的载流量(安全电流) 不是直接指出,而是“截面乘上一定的倍数”来表示,通过心算而得。 由表5-3可以看出:倍数随截面的增大而减小。
“二点五下乘以九,往上减一顺号走”说的是2. 5mm 2及以下的各种截面铝芯绝缘线,其载流量约为截面数的9倍。如2. 5mm 2导线,载流量为2. 5×9=22. 5(A)。从4mm 2及以上导线的载流量和截面数的倍数关系是顺着线号往上排,倍数逐次减l ,即4×8、6×7、10×6、16×5、25×4。
“三十五乘三点五,双双成组减点五”,说的是35mm 2的导线载流量为截面数的3. 5倍,即35×3. 5=122. 5(A)。
从50mm 2及以上的导线,其载流量与截面数之间的倍数关系变为两个两个线号成一组,倍数依次减0. 5。即50、70mm 2导线的载流量为截面数的3倍;95、120mm”导线载流量是其截面积数的2. 5倍,依此类推。
“条件有变加折算,高温九折铜升级”。上述口诀是铝芯绝缘线、明敷在环境温度25℃的条件下而定的。若铝芯绝缘线明敷在环境温度长期高于25℃的地区,导线载流量可按上述口诀计算方法算出,然后再打九折即可。 当使用的不是铝线而是铜芯绝缘线,它的载流量要比同规格铝线略大一些,可按上述口诀方法算出比铝线加大一个线号的载流量。如16mm2铜线的载流量,可按25mm 2铝线计算。
转载请注明出处范文大全网 » 鱼线的线号与线径对照表